Setting up the GFortran Compiler
This article provides instructions for installing the free GFortran compilers and testing your setup.
There are four GFortran compilers:
- GFortran 4.2: Compatible with PSCAD v4.3 to v4.6
- GFortran 4.6: Compatible with PSCAD v4.6 and v5.0
- GFortran 8.1: Compatible with PSCAD v5.0 and v5.1
- GFortran 13.2: Compatible with PSCAD v5.1
Three different installers are available for installing GFortran.
1. Alongside PSCAD - For v5.0 and older
For PSCAD v5.0 and older, which uses the multiproduct InstallShield Wizard installer for PSCAD, simply ensure to also select the GFortran compiler/s when prompted in the installer:
PSCAD X4 PSCAD V5

Note - GFortran must be installed on "C-Drive". It is not supported to install GFortran on a non-c-drive.
Log out, log back in on your machine, and test your setup as per this article before compiling your own cases.
2. Using the InstallShield Wizard
The InstallShield Wizard installer is supported for GFortran 4.2 and 4.6.
If running from the PSCAD Installation Package, unzip the package, open the "GFortran" sub-folder, right-click on "setup.exe", and select the option to "Run as administrator".

Note - GFortran must be installed on "C-Drive". It is not supported to install GFortran on a non-c-drive.
Log out, log back in on your machine, and test your setup as per this article before compiling your own cases.
3. Silent Installations - On Multiple Machines
Please refer to the following two articles regarding silent intallations:
- Best practices for silent installations (InstallShield Wizard and Installer Utility):
https://www.pscad.com/knowledge-base/article/879
- Silent installations when using the Installer Utility:
https://www.pscad.com/knowledge-base/article/715
Note - GFortran must be installed on "C-Drive". It is not supported to install GFortran on a non-c-drive.
Log out, log back in on your machine, and test your setup as per this article before compiling your own cases.
4. Using the Installer Utility
Note - Refer to this article for setting up prompting for the selection of the Program Folder during the installation.
a. Obtain the download as follows:
- For GFortran v4.2, download the software from this link, unzip the top-level file called “GFortran42_Installer.zip”, and save the files to a folder on a local drive (e.g. desktop). Do not unzip any of the other downloaded zipped sub-files.
- For GFortran v4.6, download the software from this link, unzip the top-level file called “GFortran46_Installer.zip”, and save the files to a folder on a local drive (e.g. desktop). Do not unzip any of the other downloaded zipped sub-files.
- For GFortran 8.1, download the software from this link, unzip the top-level file called “GFortran81_Installer.zip”, and save the files to a folder on a local drive (e.g. desktop). Do not unzip any of the other downloaded zipped sub-files.
- For GFortran 13.2, download the software from this link, unzip the top-level file called “GFortran132_Installer.zip”, and save the files to a folder on a local drive (e.g. desktop). Do not unzip any of the other downloaded zipped sub-files
b. Right-click on the unzipped “Installer.exe” file, and select “Run as administrator”.

c. When prompted by the User Account Control dialog box, select the option to run this installation with Windows administrator privileges by selecting “Yes”.
d. The “Installer” will launch. You will be prompted to select a location for the Program Files.
Note - GFortran must be installed on "C-Drive". It is not supported to install GFortran on a non-c-drive.
e. When the installation is complete, you will be advised to log out and log in to Windows to apply the changes to your environment. Select OK.
f. Select OK when the "Setup Complete" message displays. The Installer will close.
g. Log out, log back in on your machine, and test your setup as per this article before compiling your own cases.
5. Using the MyUpdater Utility
Refer to this article for information on installing GFortran using MyUpdater.
Note - GFortran must be installed on "C-Drive". It is not supported to install GFortran on a non-c-drive.
Log out, log back in on your machine, and test your setup as per this article before compiling your own cases.