6-Pulse Bridge

 

 

 

Description

This component is a compact representation of a DC converter, which includes a built in 6-pulse Graetz converter bridge (can be inverter or rectifier), an internal Phase Locked Oscillator (PLO), firing and valve blocking controls and firing angle (a)/extinction angle (g) measurements.  It also includes built in RC snubber circuits for each thyristor.

 

The general idea here is to eliminate the complex and tedious process of building a thyristor bridge, putting together controls, and coordinating the valve firing pulses involved in modeling an HVDC converter.

 

The 6 Pulse Bridge possesses the following external inputs and outputs:

 

 

More:

Graetz Bridge Valve Group

Internal Phase Locked Oscillator (PLO)

Firing and Blocking Control

Choosing a Converter Transformer

Snubber Circuit

Switching and Non-Linear Elements

Interpolation and Switching

Setting Up Firing Control

Input Parameters

Configuration

 

PLO

 

Valve Data

 

Internal Outputs