Segment Types

 

There are several segment types available.  Each exists for a specific purpose, but are only required if that specific function is needed as part of the component design.  Most of the time, a definition will only require two or three of the available segments.

NOTE:  Although this section does provide an assortment of simple examples, there is a huge wealth of examples in the master library itself.  Simply edit any master library definition to study its contents.

Computations

The Computations segment is an environment provided for the pre-processing of component parameter field data, as well as creating new variables, internal to the component definition. Although component parameter input may be in the most convenient form for the user, it may not be so convenient for the definition itself.  For example, the definition may require the system frequency in radians per second, but the input data field may ask the user for the same quantity in Hertz.

 

The Computations segment is the first segment considered by the compiler when the component is compiled. Due to this fact, any quantities defined here may be substituted elsewhere in any of the other segments. This segment allows both mathematical and logical expression evaluation.

NOTE:  All script processed within the Computations segment is done so before any Fortran code is constructed for EMTDC, and only considered once.  Therefore, quantities defined here are static (constant) for the remainder of the simulation.

A typical Computations segment entry must have the following standard format:

 

<Data_Type> <Name> = <Expression>

 

Where,

 

 

EXAMPLE 1:

 

A designer wants to convert an parameter with Symbol property name Vset in kV, to a per-unit value called SetPU, before it is used in component Fortran code.  An additional parameter with symbol property name Vbase in kV has also been defined for the system voltage base.

 

Parameter Field Properties for Vset

Parameter Field Properties for Vbase

 

The Computations segment could then contain a line similar to the following:

 

REAL SetPU = Vset / Vbase

 

 

 

In the above example, the designer has defined a new REAL constant entitled SetPU.  This constant may now be used in any other segment in the Script section, both in equations and/or in logical expressions.

Branch

The Branch segment is primarily for the provision electric branch information to the EMTDC Electric Network Conductance Matrix:  It is essentially an input portal for control of the EMTDC Equivalent Conductance (GEQ) Interface.  Branch design is accomplished by specifying the type and size of passive elements (i.e. lumped R, L and/or C), and to which electrical port connections they fall between.  

 

A single Branch statement represents a single electrical branch, to which is associated an impedance Z = R + jX, where Z is derived from a combination of series-connected, lumped R, L and/or C values.  The Branch segment may also be used to identify switching branches and those that contain an ideal voltage source (i.e. infinite bus).

 

A typical Branch Segment entry must have the following standard format:

 

[<Branchname> = ]  $<TO> $<FROM>  [<Keyword>]   [$]<R>  [$][<L>]  [$][<C>]

 

Where,

NOTE:  If a branch does not contain all three types of R, L and C elements, simply substitute 0.0 for the value of the element that is not present.  

 

 

EXAMPLE 2:

 

A designer wants to define a component, which represents an RC series branch, connected in parallel with a purely inductive branch, between electrical port connections N1 and N2.  These two port connections have already been defined in the Graphic section of the definition.

 

Component Graphic with Electrical Ports N1 and N2

 

The actual values of the R and C elements are to be entered though input fields (with Symbol property names R and C respectively) in the Parameters section of the definition.  The inductance value is not accessible to the user and is given a static value of 0.001 H directly.

 

Component Parameters Dialog

 

The Branch segment would then contain the following two statements:

 

$N2  $N1  $R   0.0    $C

$N2  $N1  0.0  0.001  0.0

 

These statements are equivalent to the following schematic:

 

 

The designer then decides to refer to the branches by branch name in other sections of the definition.  To achieve this, the names BRN1 and BRN2 are defined.  The designer modifies the above branch statements as follows:

 

BRN1 = $N2  $N1   $R   0.0    $C

BRN2 = $N2  $N1   0.0  0.001  0.0

NOTE:  If BRN1 and BRN2 are used in other segments, they must be preceded by the Substitution Prefix Operator ($).

 

 

 

The branch may also contain an inherent ideal source in series with the passive elements.  The Branch segment syntax allows you to indicate to the application that there is a voltage source in a particular branch as follows:

 

[<Branchname> = ]  $<TO> $<FROM>   SOURCE   [$]<R>  [$][<L>]  [$][<C>]

 

Now that PSCAD knows that there is a source in this branch, control of the source (i.e. magnitude, etc.) is then up to the user.  One way this can be accomplished is by defining the EMTDC internal variable EBR every time step, directly in the model code itself.

NOTE:  For more examples on this, edit the definition of the Voltage Source Model 2 in the master library project.

 

 

EXAMPLE 3:

 

A designer adds a resistive branch containing an ideal voltage source to the component in the previous example, which is to be connected between node N1 and a ground electrical port connection GND.  The source possesses a source resistance RS, which can be entered as a parameter.

 

The Branch segment could then contain something similar to the following:

 

BRNS = $N1  $GND SOURCE  $RS  0.0    0.0

BRN1 = $N2  $N1          $R   0.0    $C

BRN2 = $N2  $N1          0.0  0.001  0.0

 

These statements are a schematic equivalent to:

 

 

 

 

The Branch segment syntax also allows you to indicate to the application that a particular branch is a switching branch:

 

[<Branchname> = ]  <TO> <FROM>  BREAKER  <Initial_Value>

 

Where,

Fortran

The Fortran segment is where any Fortran code, defining what the component is to model, is placed.  Code entered in this segment should either exist in the form of standard Fortran, or Definition Script (or a combination of these two).  It is also possible to define a function, or call an external subroutine from this segment.

 

When using actual Fortran code in this segment, it is important to note that all lines should be preceded by the allotted six spaces.

 

 

 

EXAMPLE 4:

 

The following code is a simple example of how standard Fortran would appear in the Fortran segment.  This code defines an instantaneous voltage source magnitude VT, according to the value of a parameter Type.  If Type = 0, then the magnitude is calculated using the standard equation for a sinusoidal source with phase shift:

 

 

If Type = 1, then the source magnitude is a constant given by VDC.  FREQ and PHI are also parameters defined in the Parameters section of the definition.  TWO_PI is an EMTDC internal constant.

 

! Calculation of an AC or DC voltage source magnitude

! ---------------------------------------------------

!

!23456 Remember to precede code by at least six spaces!

!

      IF ( $TYPE .EQ. 0 ) THEN

!

! AC source

!

        $VT = $VPEAK*SIN( TWO_PI*$FREQ*TIME + $PHI )

!

      ELSE

!

! DC source

!

        $VT = $VDC

!

      ENDIF

!

 

This same code could also be written as a combination of standard Fortran and Definition Script as follows:

 

! Calculation of an AC or DC voltage source magnitude

! ---------------------------------------------------

!

!23456 Remember to precede code by at least six spaces!

!

#IF $Type == 0

!

! AC source

!

      $VT = $VPEAK*SIN( TWO_PI*$FREQ*TIME + $PHI )

!

#ELSE

!

! DC source

!

      $VT = $VDC

!

#ENDIF

!

 

Note that the above two examples have been simplified slightly. Generally speaking, the value for the 2pft function should never be allowed to simply grow larger and larger as the simulation progresses.  It should be reset to zero whenever 2pft = 2p is reached.

 

 

 

There are pros and cons to adding in-line Fortran code directly into the segment, as opposed to calling a subroutine or function.  Here are some key points to consider:

The Fortran segment is a 'smart' segment, in that code placed here will be intelligently placed in the EMTDC System Dynamics, in order to avoid problems with time step delays.  In other words, PSCAD will choose to place the code in either the DSDYN or DSOUT subroutines, according to what variables are being defined in the code, and what this component is connected to in the project.

DSDYN

This segment is identical to the Fortran segment, except that all code will be forced into the DSDYN section of the EMTDC System Dynamics.

DSOUT

This segment is identical to the Fortran section, except that all code will be forced into the DSOUT section of the EMTDC System Dynamics.

Checks

The Checks segment is used to ensure that data entered into the component parameters by the user is reasonable. If a specific condition is true, then a given warning or error message can be made to appear in the Build and Runtime Message Panes when the case is compiled.

 

A typical Checks segment entry would have the following standard format:

 

<MESSAGE TYPE> <Message> : <Expression>

 

 

EXAMPLE 5:

 

A designer's component contains an input for frequency with symbol name F.  The designer wants to ensure that only a value greater than zero is entered.

 

The Checks segment should then contain the following:

 

ERROR System frequency must be greater than zero : F > 0.0

 

Both Logical and Arithmetic Operators may be used in the expression.  For example:

 

WARNING R1 / R2 must be greater than 100 : R1 > 100*R2

 

Remember that negative logic is used in the above examples!

 

 

Help

The Help segment is useful when the user wants to provide an external HTML based help file for a particular user-defined component.  For example if the user has created an HTML document entitled help.html for example, then all that is required that the name and extension be added to the Help segment as shown below:

 

help.html

 

When a user right clicks on the component instance and selects Help from the pop-up menu, the external document indicated will open.

 

Please note the following important facts:

Comments

Add your comments / reminders / notes about the design of this component here.  Do not use this segment as a means of providing help to users.  This segment is ignored by the application and is accessible only when editing the definition.

FlyBy

The FlyBy segment provides an avenue for the designer to apply fly-by (or pop-up) help to a component.  Fly-by windows can help to provide users with a quick description of the model itself, or even individual port connections on the component. Conditional statements (#IF, #ELSE, #ENDIF, #CASE) are allowed in the FlyBy segment. This allows users to change the flyby display over custom components, depending on user input.  This is especially important when say port connections vary in dimension and/or type.

 

The FlyBy segment syntax is straightforward:

 

<Descriptive text for the component>

#IF (<condition>)

: <Port_Connection_Symbol_Name>

<Descriptive text for the component>

#ELSE

: <Port_Connection_Symbol_Name>

<Descriptive text for the component>

#ENDIF

<Descriptive text for the connection>

NOTE:  Conditional statements (#IF, #ELSE, #ENDIF, #CASE) are optional.

 

 

EXAMPLE 6:

 

A designer wants to add fly-by help to the component below:

 

 

In addition to a general description of the component, the designer wants to provide a fly-by for each of the input port connections A and B.

 

The FlyBy segment should then contain something similar to the following:

 

This is my User Component

:A

This is input A

:B

This is input B

 

If the mouse pointer is now moved over the component while on the schematic canvas, the following fly-by windows will appear:

 

 

 

 

 

 

Transformers

The Transformers segment is used both to define data for any existing mutual impedance matrices, as well as to provide dimensioning information to EMTDC regarding transformers and windings.  A single component may contain multiple mutual impedance matrices.

 

The user must include transformer information in the following parts:

According to the above description, a basic Transformers segment would appear as follows (for a classical type transformer) in general format:

 

#TRANSFORMERS <Number_of_Transformers>

#WINDINGS <Number_of_Windings>

<Prefix><Number_of_Windings> /

<Node_1> <Node_2>   <R_11> <L_11> /

<Node_2> <Node_3>   <R_12> <L_12>  <R_22> <L_22> /

...

NOTE:  The Transformers segment format is different when defining a UMEC type transformer.  For more information on the UMEC format, see the UMEC transformer component definitions in the master library, or contact the PSCAD Support Desk (support@mhi.ca).

<Prefix> is not mandatory, but is required to indicate an 'ideal' transformer matrix (i.e. already inverted).  Also, resistance values (i.e. <R_xx>) are not required if the transformer is 'ideal'.

 

Note that only the diagonal and the data below the diagonal need to be entered.  The matrix is assumed to be symmetrical.

 

 

 

EXAMPLE 7:

 

A user wants to create a non-ideal, single-phase, two-winding transformer.  The component Graphics, Parameters and other Script section has already been included.  The component electrical port connections have been set-up as shown below in the Graphic section.

 

 

The winding self and mutual resistance and inductance parameters have been defined and given symbol names R11, L11, R12, L12, R22 and L22.

 

The Transformers segment should then appear similar to the following:

 

#TRANSFORMERS 1

#WINDINGS 2

!

2 /

$A1 $B1    $R11 $L11 /

$A2 $B2    $R12 $L12  $R22 $L22 /

!

 

 

 

888 Syntax

When designing a component with more than one transformer, you can use a special syntax (called 888 syntax) so that, if all the matrix elements are identical, you can avoid entering the repetitive data.  This is especially useful if the mutual impedance matrices are very large and numerous.

 

 

 

EXAMPLE 8:

 

In the example above, the user wants to modify the component, so that it contains two identical single-phase transformers within it.  The component electrical port connections have been set-up as shown below in the Graphic section.

 

 

The Transformers segment should then appear similar to the following:

 

#TRANSFORMERS 2

#WINDINGS 2

!

2 /

$A1 $B1    $R11 $L11 /

$A2 $B2    $R12 $L12  $R22 $L22 /

!

888 /

!

$A3 $B3 /

$A4 $B4 /

 

 

 

Model-Data

The Model-Data segment is used as a way to bring input data into a user-defined subroutine, without having to declare an argument for each bit of data.  There is no specific format for text in this segment, as this format depends on READ statements within the user code.

 

When the project is compiled, PSCAD will include all text in this segment within the corresponding module Data File (*.dta), under the headings DATADSD or DATADSO.  If the subroutine is called from DSDYN, the Model-Data contents will appear in the DATADSD section; and DATADSO otherwise.

 

In order to read this information, a standard Fortran READ statement must be added to the user-defined subroutine as follows:

 

!

!  Add include file to define IUNIT

!

      INCLUDE 'fnames.h'

!

!  ...

!

      READ(IUNIT,*) ...

!

Matrix-Fill

When a project is initially compiled, PSCAD will construct a temporary logical matrix for the purpose of indicating how the electrical system is connected (i.e. how nodes and branches are put together).  The Optimise Node Ordering algorithm in PSCAD then uses this information to optimise node placement in the actual system conductance matrix.  However, only electrical nodes and branches, defined within the Branch segments of each component present in the system, are considered.  

 

Any internal node connections defined in segments other than Branch will not be included in this matrix.  Therefore, the logical matrix may have missing information, thereby reducing the effectiveness of the Optimise Node Ordering algorithm.  The Matrix-Fill segment can be used to 'help' this algorithm by providing the omitted connection information for any internal component nodes.

 

The general format for a Matrix-Fill Segment statement would appear as follows:

 

<Node_1> <Node_2> <Node_3> <Node_4> ...

 

Where <Node_#> is the Symbol name of the port connection involved.  All port connections in a single statement are assumed as connected to each other.

 

 

 

EXAMPLE 9:

 

A user creates a single-phase electrical circuit in PSCAD, which includes a classical transformer component connected as follows:

 

 

As can be seen above, there are 6 electrical nodes in this system, and therefore the system matrix will have dimension 6 x 6.  Connections internal to the transformer component cannot be determined initially by PSCAD, and so when a logical matrix for the Optimise Node Ordering algorithm is created, the transformer appears as a 'black box' as shown below:

 

 

The logical matrix for the Optimise Node Ordering algorithm would appear as follows, where X indicates a known connection:

 

 

The matrix above does not contain all of the connection information required however.  We know through the Transformers segment in the transformer component, that nodes N2, N3, N5 and N6 are all part of a mutual impedance matrix and are hence all connected together as shown below:

 

 

By adding in Matrix-Fill information, we can tell PSCAD to add connection information to the matrix so it will appear as follows, where '+' indicates a connection added by Matrix-Fill:

 

 

If the four electrical port connections on the transformer were given as follows in the Graphic section of the definition,

 

 

then the Matrix-Fill segment should appear as:

 

$A1 $B1 $A2 $B2

 

 

 

 

Note that in the above example, it assumed that all connections between the four nodes involved are possible.  If however, only connections as shown below are needed,

 

 

then the Matrix-Fill segment should appear as:

 

$A1 $B2

$A2 $B1

T-Lines

The T-Lines segment is used to specify any electrical port connections that are to be used as sending or receiving end port connections for a transmission line or cable.  The T-Lines segment is rarely needed in component design.  The general format of statements in this segment is given below:

 

<Subsystem_#> <Cond_1> <Cond_2> <Cond_3> ...

 

<Cond_#> signifies that any port connection Symbol name that is entered in this position will be the sending or receiving end port connection for that particular conductor number in the transmission line or cable properties.

 

This Segment is used only within the Transmission Line and Cable Interface components in the master library.

C

The C segment is utilized exclusively as a means to enter custom component defining C-based script for the C-Coder. Normally, this code is functionally equivalent to the custom component’s original Fortran-based script.

 

For example, here is the Fortran and C segments for the master library component Edge Triggered Monostable Multivibrator:

 

 

 

Fortran Segment

C Segment

 

There are script directives that are used exclusively in this segment.

 

See Script Directives and C-Coder for more details.

Subsystems

The Subsystems segment is used to specify and define transmission lines or cables, and how they are connected, within a single component definition. This is accomplished in via two main aspects: Defining unique subsystems and declaring which electrical connect ports belong to which subsystem, and defining the transmission segment itself and to which nodes the sending and receiving ends are connected. The general format of these statements is shown as follows (for a single, 3-phase transmission line):

 

#SUBSYSTEM <Subsystem_1_Name>

#PORT <Node_1>, <Node_2>, <Node_3>

#ENDSUBSYSTEM

 

#SUBSYSTEM <Subsystem_2_Name>

#PORT <Node_4>, <Node_5>, <Node_6>

#ENDSUBSYSTEM

 

#TLINE <Input_or_Output> <Segment_Name> <Subsystem_1_Name(<Node_1>, <Node_2>, <Node_3>)> <Subsystem_2_Name(<Node_4>, <Node_5>, <Node_6>)>

<File_Contents>

#ENDTLINE

 

<Node_X> is the name of an existing port or internal electrical node defined within the same component definition. <Input_or_Output> must be declared as INPUT or OUTPUT, depending on the choice of <File_Contents>. <Segment_Name> is the given, unique name of the transmission line or cable. <Subsystem_X> is a subsystem that has been previously defined by using a #SUBSYSTEM/#ENDSUBSYTEM directive block. <Node_X> is a node that was previously defined in the same #SUBSYSTEM/#ENDSUBSYTEM directive block.

 

Example generated by Blackbox (simpleac.pscx) using the Bergeron model *.out file as the <File_Contents>:

 

#SUBSYSTEM SS1
#PORT N, NBBF1
#ENDSUBSYSTEM

#SUBSYSTEM SS2
#PORT N_2, NBBF2
#ENDSUBSYSTEM

#TLINE OUTPUT SEGMENT_0 SS1(NBBF1(4), NBBF1(5), NBBF1(6)) SS2(NBBF2(1), NBBF2(2), NBBF2(3))
3 0     1          1         60.00000        60.00000        100000.0       0.1000000E-08   0.1000000E-08 /
1     1     0.498991043323560         651.480263770966        0.371477753870379E-03    0.371477753870379E-03    0.577525920918064  ...     
2     2     0.342410766460306         318.322113016821        0.187492671522944E-04    0.187492671522944E-04    0.576998805315474  ...     
3     3     0.338634082834414         267.045965961836        0.191764641425243E-04    0.191764641425243E-04    0.577525920918064  ...     
#ENDTLINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This segment is used predominantly by the Blackbox feature, but it can also be used in any custom component.