Parameter Form

 

The Parameter Form displays the contents of a particular category, which may be composed of several types of parameter fields that are used to input to, or output data from the component model. For example, the image below illustrates the parameter dialog (parameter form highlighted in red) for the Synchronous Machine, one of the more complex models in the PSCAD master library.

 

Synchronous Machine Component from the PSCAD Master Library

 

There are several different types of parameters fields that may be added to a category from within the parameter form. These include:

Each of these parameter field types are discussed in detail in this section (just click the links above).

NOTE: Only input parameters of type Real, Integer, Logical and Complex can be ported into a module as a signal. Boolean, Choice, Table and Text types cannot.

Adjusting Form Properties

Form properties can be adjusted by first left-clicking anywhere on the WYSIWYG display frame. The frame properties will appear in the properties form:

 

 

Parameter Form Properties and WYSIWYG Display

 

Adjust these properties as you see fit. Descriptions are given as follows:

 

Appearance:

 

Data

Layout:

Adding Parameter Fields

To add a new parameter field to your parameter form, simply click the associated Add button in the ribbon control bar:

 

 

Or right-click over the parameter form and select Add. Select the appropriate item from the sub-menu:

 

Cut, Copy, Paste and Delete of Parameter Fields

Cut, copy or paste a parameter field by using one of two methods:

To delete a field, select it and press the Delete key, or right-click and select Delete.

Navigating Through Parameter Fields

Once you have added more than field, there will of course be a need to navigate through them. In the parameter form, simply left-click on the desired parameter field to view its properties and content.

 

Ordering Parameter Fields

Once you have added more than one parameter field, there may be a need to re-order their sequence. To move a field up or down, select it and press the associated button in the ribbon control bar:

 

 

Or, select a parameter field, right-click and select one of the Move options:

 

Toggling Symbol View

By default, the parameter form displays the Display Name property for each parameter field. If you prefer to display the Symbol instead, then you can toggle back and forth. Simply click the Toggle Symbol View button in the ribbon control bar:

 

 

Or, right-click on a parameter field and select Toggle Symbol View.