The Books branch is used to house all book (*.epbx) files that are a part of the workspace. Books are collections of sheets, on which graphs may be placed and laid out for plotting and displaying curves.
When a book is created or opened, the name and description will appear by default in the workspace pane, under the Books branch. It is of course possible to open multiple books, and these will be listed in the order in which they are opened. One or more sheets, which display graphs or notes, may be included with each book (the sheets may be sorted).

See Features and Operations | Books for more on creating, loading and saving books and sheets.
Right-clicking directly on the Books branch will bring up a menu as shown below:

The following list describes the functions of this pop-up menu:
New...: Invokes the New Book dialog, which creates a new book (*.epbx) file. See Creating a New Book.
Open...: Open an existing book file.
Save All: Saves all books in the workspace.
View Parameter Grid: Opens the Parameter Grid pane in book-mode.
Help: Opens the corresponding topic in the online help.
Right-clicking directly on a Book will bring up a menu as shown below:

The following list describes the functions of this pop-up menu:
Properties...: Invokes the Book Properties dialog. See Editing Book Properties.
View Parameter Grid: Opens the Parameter Grid pane in book-mode.
New Sheet: Adds a new sheet to the book.
Paste Sheet: Pastes a copied sheet to the book.
Clone Book: Clones, or exactly duplicates, the book. See for Cloning a Book more details. There are two choices when cloning a book: With Data and Without Data.
With Data: Clones the book with links to the datasets that are referenced in the original book.
Without Data: Clones the book without links to the datasets that are referenced in the original book.
Save: Saves the book.
Save As...: Save the book to a new file.
Consolidate: Invokes the consolidator tool to consolidate this book, and any referenced data sets.
Unload: Unloads the book.
Reopen: Reopens the book.
Move: Moves the book in the local stack of books as indicated.
Show In Folder: Selecting this item will open the Windows file explorer to the folder location where that particular file is located. See Show in Folder.
Relink Curves...: See Dataset Reference and Linking.
Delink All Curves: See Dataset Reference and Linking.
Relink All Curves: See Dataset Reference and Linking.
View Data Reference Pane: Opens the Data Reference pane, in not already open.
Sort Sheets: Sort the sheets in this book by either Name or Description.
Help: Opens the corresponding topic in the online help.
A single book may contain multiple sheets. Each sheet represents a display canvas, on which plotting tools may be laid out to display plotted data. See Features and Operations | Sheets for more on creating, loading and saving sheets.
Right-clicking directly on a Sheet will bring up a menu as shown below:

The following list describes the functions of this pop-up menu:
Properties...: Invokes the Sheet Properties dialog. See Editing Sheet Properties.
View Parameter Grid: Opens the Parameter Grid pane in sheet-mode.
Copy Sheet: Copies the sheet to the clipboard, for pasting in this or another book.
Delete Sheet: Deletes the sheet.
Relink Curves...: See Dataset Reference and Linking.
Move: Moves the sheet in the local stack of sheets as indicated.
Help: Opens the corresponding topic in the online help.