Curves

 

A curve can be described as a graphical representation of a string of data points, where each point is associated with a time value.  Curves are created by linking a dataset record, to which represents a scalar set of data defined in the dataset source file.  

Adding a New Curve to a Graph

Adding a curve to a graph can be accomplished a couple of different ways:

  1. Drag and Drop Method:  Hold down the Ctrl key.  Left-click and hold over one or more records in a dataset, from which you would like to extract the curve.  Drag the mouse pointer over a graph and release the mouse button.  See Drag and Drop for more details on this.

  2. Manual Add Method:  Right-click on one or more records in a dataset, from which you would like to extract the curve.  Select Copy.  Select the desired graph with a left-click, then right-click and select Paste Curve(s).

Record Context Menu

Paste Curve in Graph

 

Note when copying multiple records, a paste action will by default place all curves within a single graph (same as multiple record select + Ctrl + left mouse drag). If a single curve per graph is preferred, use multiple record select + Shift + left mouse drag.

Curve Legends

Once a curve has been added to a Graph, the curve title will appear in the curve legend.

 

 

Curve Order

Once multiple curves have been added to a graph, you may change the order in which they appear.  Ordering curves can be accomplished in one of two ways:

  1. Drag and Drop:  Left-click and hold over the curve in the curve legend.  Drag the mouse pointer to a new position in the curve legend and release the mouse button.  See Drag and Drop for more details on this.

  2. Right-Click Menu:  Right-click over the corresponding curve legend and select one of the following from the pop-up menu:  Move to the Start or Move to the End.

 

Curve Link To

Right-click over the curve title and select Link To, to display from which dataset the record representing the curve is referenced. If you have multiple, identical datasets loaded, you can use the menu function to quickly switch between them.

 

See Dataset Linking for more details.

Generate New Record

Select this option to generate a new record, based on the modifications made to this specific curve. Note that this operation will convert the dataset, from which this curve is linked, to a new, identical one containing this modified record.

 

Warning: Consult Exporting/Saving Datasets before proceeding.

Curve Smooth

Right-click over the curve title and select Smooth, to apply a smoothing function to the curve. You will be asked to a enter a time constant in seconds. The smoothing algorithm is described in Record Wizard | Math Functions.

NOTE: If you need to save your modifications to the curve, please see Generate New Record and Exporting/Saving Datasets before proceeding.

There is also an Unsmooth function, which reverts the last Smooth operation.

Translating or Scaling a Curve

Curves may be translated in both the x and y directions, or scaled via a scale factor.

Locating Minimum or Maximum Value

Right-click over the curve title and select Locate Min or Locate Max Value. Enerplot will show the exact point on the curve (using a red crosshair) that is the maximum or minimum value. If the Data View pane is open, the correct data point will also be shown there.

Cut/Copy/Paste an Existing Curve

Right-click over the curve title and select either Cut Curve or Copy Curve, depending on what you want to do.  Right-click over any graph and then select Paste Curve to paste the curve.  The curve should then appear in the corresponding curve legend.

Copy Data to Clipboard

If a particular curve contains data, you have the option of copying all or a portion of this single curve data set to the clipboard.  Right-click over the corresponding curve name, select Copy Data to Clipboard and then select one of the following from the pop-up menu:

The data is copied in tab delimited format for easy migration into common data analysis software.

Adjusting Curve Properties

Left double-click on the desired curve in the curve legend, or right-click the curve and select Curve Properties....

 

 

This will bring up the Curve Settings dialog window.

 

Identification

The following list describes the parameters in this section:

Digital

These options are only considered if the curve is part of a polygraph.  Digital style controls the properties the curve traces when they are in Digital mode.  The following list describes the parameters in this section:

Display

The following list describes the parameters in this section:

Scaling

These options are provided to allow for adjustment of the curve in the graph.

 

The following list describes the parameters in this section:

NOTE: If you need to save your modifications to the curve, please see Generate New Record and Exporting/Saving Datasets before proceeding.

Style

The following list describes the parameters in this section:

Any changes may be reverted at any time by readjusting these parameter inputs.