The output of this component is used specifically for controlling Single-Phase Breaker and Three-Phase Breaker component states.
Using this component, the user may initially set the state of the breaker being controlled to OFF (open) or ON (closed). One or two breaker options may also be selected.
The first operation and second operations will either be OFF (open) or ON (close) depending on the initial state. The output of this block should be connected to a Data Label with the Breaker Name of the breaker being controlled.
The Timed Breaker Logic component may be linked to a breaker component as follows:

More: |
Name for Identification |
Text |
Optional text parameter for identification of the component. |
||
# of Breaker Operations |
|
Choice |
|
Select 1 or 2 |
|
|
|
|
|
Initial State |
|
Choice |
|
Select Closed or Open |
|
|
|
|
|
Time of First Breaker Operation |
|
REAL |
Variable |
Enter the time of first breaker operation. The breaker will change it's state from the initial state at this time [s] |
|
|
|
|
|
Time of 2nd Breaker Operation |
|
REAL |
Variable |
Enter the time of second breaker operation. The breaker will revert back to the original state at this time [s] |