Graphs¶
Frames¶
Graph Frame¶
-
class
mhi.enerplot.GraphFrame¶ Graph Frame
A container which can hold one or more Graph Panels, stacked vertically, with a common x-axis.
-
add_overlay_graph()¶ Add a new overly graph panel to the Graph Frame.
Returns: the newly added graph panel. Return type: GraphPanel
-
add_poly_graph()¶ Add a new poly-graph panel to the Graph Frame.
Returns: the newly added graph panel. Return type: GraphPanel
-
remove(*graphs)¶ Remove graphs from the Graph Frame
-
attributes(**kwargs)¶ Set or get a component’s attributes
A component’s attributes are used to describe the component’s location and size relative to its parent.
Parameters: **kwargs – key=value arguments Returns: The component’s current attributes. Return type: dict See also
-
book¶ The book the component belongs to (read-only)
-
book_name¶ The book the component belongs to (read-only)
-
classid¶ The classid of the component (read-only)
-
copy()¶ Copy the component to the clipboard
-
copy_as_bitmap()¶ Copy component to clipboard as a bitmap
-
copy_as_metafile()¶ Copy component to clipboard as a metafile
-
cut()¶ Remove the component to the clipboard
-
extents(x=None, y=None, width=None, height=None)¶ Get or set the component’s position and size
If all parameters are given, the position and size is set. If all parameters are omitted, the current extents are returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
- width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current extents of the component
Return type: Tuple[x,y,width,height]
-
find([classid,] [key=value, ...])¶ Find the (singular) component that matches the given criteria, or None if no matching component can be found. Raises an exception if more than one component matches the given criteria.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
find_all([classid,] [key=value, ...])¶ Find all components that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the list of matching components
Return type: List[Component]
-
find_first([classid,] [key=value, ...])¶ Find a component that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
id¶ The id of the component (read-only)
-
list(classid=None)¶ List all the components contained inside this object, possibly restricted to a certain classid.
Parameters: classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”. Returns: the list of components Return type: List[Component]
-
lock_markers(lock=True, *, delta=None)¶ Lock (or unlock) markers to a fixed offset from each other.
Parameters: - lock (bool) – set to
Falseto unlock the marker - delta (float) – used to specify lock offset (optional)
Examples:
fft.lock_markers() fft.lock_markers(delta=1/50) fft.lock_markers(False)
- lock (bool) – set to
-
main¶ A reference to the
Applicationobject that returned thisRemotableobject.
-
parent()¶ Retrieve the owner of this component
-
paste()¶ Paste the component(s) from the clipboard to this canvas
-
position(x=None, y=None)¶ Get or set the component’s position.
If the x & y parameters are given, the position is set. If they are omitted, the current position is returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
Returns: The current location of the component
Return type: Tuple[x,y]
-
properties(paramlist='', **kwargs)¶ Set or get a component’s properties
A component’s properties are used to describe the component’s appearance or control the component’s behaviour.
Parameters: **kwargs – key=value arguments Returns: The component’s current property values Return type: dict See also
-
reset_extents()¶ Reset the graph’s extents
-
reset_limits()¶ Reset the graph’s limits
-
set_markers(x=None, o=None, *, delta=None)¶ Set the X and/or O marker positions.
If both
xandoare specified,deltacannot be given.If
deltais given, the O-marker is positioned the specified distance after the X-marker, unless theovalue is specified in which case the X-marker is positioned the specified distance before the O-marker.If the markers were hidden, they will automatically be shown.
If the markers are “locked together”, they will remain locked together, but with their relative offset defined by their new positions.
Parameters: - x (float) – new x-marker position
- o (float) – new o-marker position
- delta (float) – distance between x & o markers
Examples
The following are equivalent, and set the markers 1 cycle apart, assuming a 60Hz waveform:
graph_frame.set_markers(0.1, 0.11666667) graph_frame.set_markers(0.1, delta=0.01666667) graph_frame.set_markers(0.1, delta=1/60) graph_frame.set_markers(delta=1/60, x=0.1) graph_frame.set_markers(delta=1/60, o=0.11666667)
-
show_glyphs(show=True)¶ Set the curve glyph visibility.
Parameters: show (bool) – Set to Falseto turn off the curve glyphs.
-
show_grid(show=True)¶ Set the grid’s visibility.
Parameters: show (bool) – Set to Falseto turn off the grid.
-
show_markers(show=True)¶ Show (or hide) the X/O markers
-
show_ticks(show=True)¶ Set the tick visibility.
Parameters: show (bool) – Set to Falseto turn off the tick markers.
-
show_x_intercept(show=True)¶ Set the X intercept visibility on or off
-
show_y_intercept(show=True)¶ Set the Y intercept visibility on or off
-
size(width=None, height=None)¶ Get or set the component’s size
If the width & height parameters are given, the size is set. If they are omitted, the current size is returned.
Parameters: - width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current size of the component
Return type: Tuple[width, height]
-
title¶ The title of the frame
-
toggle_curve_glyphs()¶ Toggle curve glyphs on or off
-
toggle_grid_lines()¶ Toggle grid lines on or off
-
toggle_markers()¶ Toggle X/O markers
-
toggle_tick_marks()¶ Toggle tick marks on or off
-
toggle_x_intercept()¶ Toggle X intercept on or off
-
toggle_y_intercept()¶ Toggle Y intercept on or off
-
zoom(xmin=None, xmax=None, ymin=None, ymax=None, *, compute_x_grid=True, compute_y_grid=True)¶ Alter the graph’s viewport
-
zoom_extents(x_extents=True, y_extents=True)¶ Reset the graph’s zoom to the X and/or Y extents. By default, both X and Y axis zoom is affected.
Parameters: - x_extents (bool) – set to False to not affect X-axis
- y_extents (bool) – set to False to not affect Y-axis
-
zoom_limits(x_limits=True, y_limits=True)¶ Reset the graph’s zoom to the X and/or Y limits. By default, both X and Y axis zoom is affected.
Parameters: - x_limits (bool) – set to False to not affect X-axis
- y_limits (bool) – set to False to not affect Y-axis
-
zoom_x_extents()¶ Reset the graph’s zoom for the X-axis to the X extents.
-
zoom_x_limits()¶ Reset the graph’s zoom for the X-axis to the X limits.
-
zoom_y_extents()¶ Reset the graph’s zoom for the Y-axis to the Y extents.
-
zoom_y_limits()¶ Reset the graph’s zoom for the Y-axis to the Y limits.
-
Plot Frame¶
-
class
mhi.enerplot.PlotFrame¶ Plot Frame
A container which holds a X-Y plot graph containing 1 or more curves.
-
add_curves(*channels)¶ Add one or more channels to the X-Y plot.
For every pair of channels added, one X-Y curve is created.
Parameters: *channels (Channel) – curves to add to X-Y plot frame
-
paste_curve()¶ Paste a curve from the clipboard into the graph
-
polar()¶ Switch the plot to Polar mode (magnitude & phase)
-
rectangular()¶ Switch the plot to Rectangular mode (X-Y)
-
attributes(**kwargs)¶ Set or get a component’s attributes
A component’s attributes are used to describe the component’s location and size relative to its parent.
Parameters: **kwargs – key=value arguments Returns: The component’s current attributes. Return type: dict See also
-
book¶ The book the component belongs to (read-only)
-
book_name¶ The book the component belongs to (read-only)
-
classid¶ The classid of the component (read-only)
-
copy()¶ Copy the component to the clipboard
-
copy_as_bitmap()¶ Copy component to clipboard as a bitmap
-
copy_as_metafile()¶ Copy component to clipboard as a metafile
-
cut()¶ Remove the component to the clipboard
-
extents(x=None, y=None, width=None, height=None)¶ Get or set the component’s position and size
If all parameters are given, the position and size is set. If all parameters are omitted, the current extents are returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
- width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current extents of the component
Return type: Tuple[x,y,width,height]
-
find([classid,] [key=value, ...])¶ Find the (singular) component that matches the given criteria, or None if no matching component can be found. Raises an exception if more than one component matches the given criteria.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
find_all([classid,] [key=value, ...])¶ Find all components that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the list of matching components
Return type: List[Component]
-
find_first([classid,] [key=value, ...])¶ Find a component that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
id¶ The id of the component (read-only)
-
list(classid=None)¶ List all the components contained inside this object, possibly restricted to a certain classid.
Parameters: classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”. Returns: the list of components Return type: List[Component]
-
main¶ A reference to the
Applicationobject that returned thisRemotableobject.
-
parent()¶ Retrieve the owner of this component
-
paste()¶ Paste the component(s) from the clipboard to this canvas
-
position(x=None, y=None)¶ Get or set the component’s position.
If the x & y parameters are given, the position is set. If they are omitted, the current position is returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
Returns: The current location of the component
Return type: Tuple[x,y]
-
properties(paramlist='', **kwargs)¶ Set or get a component’s properties
A component’s properties are used to describe the component’s appearance or control the component’s behaviour.
Parameters: **kwargs – key=value arguments Returns: The component’s current property values Return type: dict See also
-
reset_extents()¶ Reset the graph’s extents
-
reset_limits()¶ Reset the graph’s limits
-
show_glyphs(show=True)¶ Set the curve glyph visibility.
Parameters: show (bool) – Set to Falseto turn off the curve glyphs.
-
show_grid(show=True)¶ Set the grid’s visibility.
Parameters: show (bool) – Set to Falseto turn off the grid.
-
show_ticks(show=True)¶ Set the tick visibility.
Parameters: show (bool) – Set to Falseto turn off the tick markers.
-
show_x_intercept(show=True)¶ Set the X intercept visibility on or off
-
show_y_intercept(show=True)¶ Set the Y intercept visibility on or off
-
size(width=None, height=None)¶ Get or set the component’s size
If the width & height parameters are given, the size is set. If they are omitted, the current size is returned.
Parameters: - width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current size of the component
Return type: Tuple[width, height]
-
title¶ The title of the frame
-
toggle_curve_glyphs()¶ Toggle curve glyphs on or off
-
toggle_grid_lines()¶ Toggle grid lines on or off
-
toggle_tick_marks()¶ Toggle tick marks on or off
-
toggle_x_intercept()¶ Toggle X intercept on or off
-
toggle_y_intercept()¶ Toggle Y intercept on or off
-
zoom(xmin=None, xmax=None, ymin=None, ymax=None, *, compute_x_grid=True, compute_y_grid=True)¶ Alter the graph’s viewport
-
zoom_extents(x_extents=True, y_extents=True)¶ Reset the graph’s zoom to the X and/or Y extents. By default, both X and Y axis zoom is affected.
Parameters: - x_extents (bool) – set to False to not affect X-axis
- y_extents (bool) – set to False to not affect Y-axis
-
zoom_limits(x_limits=True, y_limits=True)¶ Reset the graph’s zoom to the X and/or Y limits. By default, both X and Y axis zoom is affected.
Parameters: - x_limits (bool) – set to False to not affect X-axis
- y_limits (bool) – set to False to not affect Y-axis
-
zoom_x_extents()¶ Reset the graph’s zoom for the X-axis to the X extents.
-
zoom_x_limits()¶ Reset the graph’s zoom for the X-axis to the X limits.
-
zoom_y_extents()¶ Reset the graph’s zoom for the Y-axis to the Y extents.
-
zoom_y_limits()¶ Reset the graph’s zoom for the Y-axis to the Y limits.
-
FFT Graph Frame¶
-
class
mhi.enerplot.FFTFrame¶ FFT Graph Frame
A container which holds an overlay graph, as well as a magnitude and phase graph for automatic harmonic analysis of the curve(s) in the overlay graph.
-
add_curves(*channels)¶ Add one or more channels to the FFT Graph
Parameters: *channels (Channel) – curves to add to graph
-
paste_curve()¶ Paste a curve from the clipboard into the top graph
-
attributes(**kwargs)¶ Set or get a component’s attributes
A component’s attributes are used to describe the component’s location and size relative to its parent.
Parameters: **kwargs – key=value arguments Returns: The component’s current attributes. Return type: dict See also
-
book¶ The book the component belongs to (read-only)
-
book_name¶ The book the component belongs to (read-only)
-
classid¶ The classid of the component (read-only)
-
copy()¶ Copy the component to the clipboard
-
copy_as_bitmap()¶ Copy component to clipboard as a bitmap
-
copy_as_metafile()¶ Copy component to clipboard as a metafile
-
cut()¶ Remove the component to the clipboard
-
extents(x=None, y=None, width=None, height=None)¶ Get or set the component’s position and size
If all parameters are given, the position and size is set. If all parameters are omitted, the current extents are returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
- width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current extents of the component
Return type: Tuple[x,y,width,height]
-
find([classid,] [key=value, ...])¶ Find the (singular) component that matches the given criteria, or None if no matching component can be found. Raises an exception if more than one component matches the given criteria.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
find_all([classid,] [key=value, ...])¶ Find all components that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the list of matching components
Return type: List[Component]
-
find_first([classid,] [key=value, ...])¶ Find a component that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
id¶ The id of the component (read-only)
-
list(classid=None)¶ List all the components contained inside this object, possibly restricted to a certain classid.
Parameters: classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”. Returns: the list of components Return type: List[Component]
-
lock_markers(lock=True, *, delta=None)¶ Lock (or unlock) markers to a fixed offset from each other.
Parameters: - lock (bool) – set to
Falseto unlock the marker - delta (float) – used to specify lock offset (optional)
Examples:
fft.lock_markers() fft.lock_markers(delta=1/50) fft.lock_markers(False)
- lock (bool) – set to
-
main¶ A reference to the
Applicationobject that returned thisRemotableobject.
-
parent()¶ Retrieve the owner of this component
-
paste()¶ Paste the component(s) from the clipboard to this canvas
-
position(x=None, y=None)¶ Get or set the component’s position.
If the x & y parameters are given, the position is set. If they are omitted, the current position is returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
Returns: The current location of the component
Return type: Tuple[x,y]
-
properties(paramlist='', **kwargs)¶ Set or get a component’s properties
A component’s properties are used to describe the component’s appearance or control the component’s behaviour.
Parameters: **kwargs – key=value arguments Returns: The component’s current property values Return type: dict See also
-
reset_extents()¶ Reset the graph’s extents
-
reset_limits()¶ Reset the graph’s limits
-
set_markers(x=None, o=None, *, delta=None)¶ Set the X and/or O marker positions.
If both
xandoare specified,deltacannot be given.If
deltais given, the O-marker is positioned the specified distance after the X-marker, unless theovalue is specified in which case the X-marker is positioned the specified distance before the O-marker.If the markers were hidden, they will automatically be shown.
If the markers are “locked together”, they will remain locked together, but with their relative offset defined by their new positions.
Parameters: - x (float) – new x-marker position
- o (float) – new o-marker position
- delta (float) – distance between x & o markers
Examples
The following are equivalent, and set the markers 1 cycle apart, assuming a 60Hz waveform:
graph_frame.set_markers(0.1, 0.11666667) graph_frame.set_markers(0.1, delta=0.01666667) graph_frame.set_markers(0.1, delta=1/60) graph_frame.set_markers(delta=1/60, x=0.1) graph_frame.set_markers(delta=1/60, o=0.11666667)
-
show_glyphs(show=True)¶ Set the curve glyph visibility.
Parameters: show (bool) – Set to Falseto turn off the curve glyphs.
-
show_grid(show=True)¶ Set the grid’s visibility.
Parameters: show (bool) – Set to Falseto turn off the grid.
-
show_markers(show=True)¶ Show (or hide) the X/O markers
-
show_ticks(show=True)¶ Set the tick visibility.
Parameters: show (bool) – Set to Falseto turn off the tick markers.
-
show_x_intercept(show=True)¶ Set the X intercept visibility on or off
-
show_y_intercept(show=True)¶ Set the Y intercept visibility on or off
-
size(width=None, height=None)¶ Get or set the component’s size
If the width & height parameters are given, the size is set. If they are omitted, the current size is returned.
Parameters: - width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current size of the component
Return type: Tuple[width, height]
-
title¶ The title of the frame
-
toggle_curve_glyphs()¶ Toggle curve glyphs on or off
-
toggle_grid_lines()¶ Toggle grid lines on or off
-
toggle_markers()¶ Toggle X/O markers
-
toggle_tick_marks()¶ Toggle tick marks on or off
-
toggle_x_intercept()¶ Toggle X intercept on or off
-
toggle_y_intercept()¶ Toggle Y intercept on or off
-
zoom(xmin=None, xmax=None, ymin=None, ymax=None, *, compute_x_grid=True, compute_y_grid=True)¶ Alter the graph’s viewport
-
zoom_extents(x_extents=True, y_extents=True)¶ Reset the graph’s zoom to the X and/or Y extents. By default, both X and Y axis zoom is affected.
Parameters: - x_extents (bool) – set to False to not affect X-axis
- y_extents (bool) – set to False to not affect Y-axis
-
zoom_limits(x_limits=True, y_limits=True)¶ Reset the graph’s zoom to the X and/or Y limits. By default, both X and Y axis zoom is affected.
Parameters: - x_limits (bool) – set to False to not affect X-axis
- y_limits (bool) – set to False to not affect Y-axis
-
zoom_x_extents()¶ Reset the graph’s zoom for the X-axis to the X extents.
-
zoom_x_limits()¶ Reset the graph’s zoom for the X-axis to the X limits.
-
zoom_y_extents()¶ Reset the graph’s zoom for the Y-axis to the Y extents.
-
zoom_y_limits()¶ Reset the graph’s zoom for the Y-axis to the Y limits.
-
Graph Panel¶
-
class
mhi.enerplot.GraphPanel¶ Graph Panel
-
add_curves(*channels)¶ Add one or more channels to a graph
Parameters: *channels (Channel) – curves to add to graph
-
paste_curve()¶ Paste a curve from the clipboard into the graph
-
remove(*curves)¶ Remove curves from the Graph Panel
-
attributes(**kwargs)¶ Set or get a component’s attributes
A component’s attributes are used to describe the component’s location and size relative to its parent.
Parameters: **kwargs – key=value arguments Returns: The component’s current attributes. Return type: dict See also
-
book¶ The book the component belongs to (read-only)
-
book_name¶ The book the component belongs to (read-only)
-
classid¶ The classid of the component (read-only)
-
copy()¶ Copy the component to the clipboard
-
copy_as_bitmap()¶ Copy component to clipboard as a bitmap
-
copy_as_metafile()¶ Copy component to clipboard as a metafile
-
cut()¶ Remove the component to the clipboard
-
extents(x=None, y=None, width=None, height=None)¶ Get or set the component’s position and size
If all parameters are given, the position and size is set. If all parameters are omitted, the current extents are returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
- width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current extents of the component
Return type: Tuple[x,y,width,height]
-
find([classid,] [key=value, ...])¶ Find the (singular) component that matches the given criteria, or None if no matching component can be found. Raises an exception if more than one component matches the given criteria.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
find_all([classid,] [key=value, ...])¶ Find all components that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the list of matching components
Return type: List[Component]
-
find_first([classid,] [key=value, ...])¶ Find a component that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
id¶ The id of the component (read-only)
-
list(classid=None)¶ List all the components contained inside this object, possibly restricted to a certain classid.
Parameters: classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”. Returns: the list of components Return type: List[Component]
-
main¶ A reference to the
Applicationobject that returned thisRemotableobject.
-
parent()¶ Retrieve the owner of this component
-
paste()¶ Paste the component(s) from the clipboard to this canvas
-
position(x=None, y=None)¶ Get or set the component’s position.
If the x & y parameters are given, the position is set. If they are omitted, the current position is returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
Returns: The current location of the component
Return type: Tuple[x,y]
-
properties(paramlist='', **kwargs)¶ Set or get a component’s properties
A component’s properties are used to describe the component’s appearance or control the component’s behaviour.
Parameters: **kwargs – key=value arguments Returns: The component’s current property values Return type: dict See also
-
reset_extents()¶ Reset the graph’s extents
-
reset_limits()¶ Reset the graph’s limits
-
show_glyphs(show=True)¶ Set the curve glyph visibility.
Parameters: show (bool) – Set to Falseto turn off the curve glyphs.
-
show_grid(show=True)¶ Set the grid’s visibility.
Parameters: show (bool) – Set to Falseto turn off the grid.
-
show_ticks(show=True)¶ Set the tick visibility.
Parameters: show (bool) – Set to Falseto turn off the tick markers.
-
show_x_intercept(show=True)¶ Set the X intercept visibility on or off
-
show_y_intercept(show=True)¶ Set the Y intercept visibility on or off
-
size(width=None, height=None)¶ Get or set the component’s size
If the width & height parameters are given, the size is set. If they are omitted, the current size is returned.
Parameters: - width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current size of the component
Return type: Tuple[width, height]
-
toggle_curve_glyphs()¶ Toggle curve glyphs on or off
-
toggle_grid_lines()¶ Toggle grid lines on or off
-
toggle_tick_marks()¶ Toggle tick marks on or off
-
toggle_x_intercept()¶ Toggle X intercept on or off
-
toggle_y_intercept()¶ Toggle Y intercept on or off
-
zoom(xmin=None, xmax=None, ymin=None, ymax=None, *, compute_x_grid=True, compute_y_grid=True)¶ Alter the graph’s viewport
-
zoom_extents(x_extents=True, y_extents=True)¶ Reset the graph’s zoom to the X and/or Y extents. By default, both X and Y axis zoom is affected.
Parameters: - x_extents (bool) – set to False to not affect X-axis
- y_extents (bool) – set to False to not affect Y-axis
-
zoom_limits(x_limits=True, y_limits=True)¶ Reset the graph’s zoom to the X and/or Y limits. By default, both X and Y axis zoom is affected.
Parameters: - x_limits (bool) – set to False to not affect X-axis
- y_limits (bool) – set to False to not affect Y-axis
-
zoom_x_extents()¶ Reset the graph’s zoom for the X-axis to the X extents.
-
zoom_x_limits()¶ Reset the graph’s zoom for the X-axis to the X limits.
-
zoom_y_extents()¶ Reset the graph’s zoom for the Y-axis to the Y extents.
-
zoom_y_limits()¶ Reset the graph’s zoom for the Y-axis to the Y limits.
-
Curves¶
-
class
mhi.enerplot.Curve¶ Graph Curve
-
channel()¶ Retrieve the channel associated with a curve
-
generate_new_record()¶ Your description here
-
attributes(**kwargs)¶ Set or get a component’s attributes
A component’s attributes are used to describe the component’s location and size relative to its parent.
Parameters: **kwargs – key=value arguments Returns: The component’s current attributes. Return type: dict See also
-
book¶ The book the component belongs to (read-only)
-
book_name¶ The book the component belongs to (read-only)
-
classid¶ The classid of the component (read-only)
-
copy()¶ Copy the component to the clipboard
-
copy_as_bitmap()¶ Copy component to clipboard as a bitmap
-
copy_as_metafile()¶ Copy component to clipboard as a metafile
-
cut()¶ Remove the component to the clipboard
-
decreasing()¶ Test if a trace contains strictly decreasing values.
Returns: Trueif every value is smaller than the previous one.Return type: bool
-
extents(x=None, y=None, width=None, height=None)¶ Get or set the component’s position and size
If all parameters are given, the position and size is set. If all parameters are omitted, the current extents are returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
- width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current extents of the component
Return type: Tuple[x,y,width,height]
-
find([classid,] [key=value, ...])¶ Find the (singular) component that matches the given criteria, or None if no matching component can be found. Raises an exception if more than one component matches the given criteria.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
find_all([classid,] [key=value, ...])¶ Find all components that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the list of matching components
Return type: List[Component]
-
find_first([classid,] [key=value, ...])¶ Find a component that matches the given criteria, or None if no matching component can be found.
Parameters: - classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”.
- key=value – additional parameters which must be matched.
Returns: the found component or None
Return type:
-
id¶ The id of the component (read-only)
-
increasing()¶ Test if a trace contains strictly increasing values.
A strictly increase trace is suitable to use as the domain of a dataset.
Returns: Trueif every value is larger than the previous one.Return type: bool
-
list(classid=None)¶ List all the components contained inside this object, possibly restricted to a certain classid.
Parameters: classid (str) – one of “GraphFrame”, “PlotFrame”, “FFTFrame”, “Divider”, or “Sticky”. Returns: the list of components Return type: List[Component]
-
main¶ A reference to the
Applicationobject that returned thisRemotableobject.
-
parent()¶ Retrieve the owner of this component
-
paste()¶ Paste the component(s) from the clipboard to this canvas
-
position(x=None, y=None)¶ Get or set the component’s position.
If the x & y parameters are given, the position is set. If they are omitted, the current position is returned.
Parameters: - x (int) – The component’s new x location on the sheet
- y (int) – The component’s new y location on the sheet
Returns: The current location of the component
Return type: Tuple[x,y]
-
properties(paramlist='', **kwargs)¶ Set or get a component’s properties
A component’s properties are used to describe the component’s appearance or control the component’s behaviour.
Parameters: **kwargs – key=value arguments Returns: The component’s current property values Return type: dict See also
-
size(width=None, height=None)¶ Get or set the component’s size
If the width & height parameters are given, the size is set. If they are omitted, the current size is returned.
Parameters: - width (int) – The component’s new width
- height (int) – The component’s new height
Returns: The current size of the component
Return type: Tuple[width, height]
-