Input Controls¶
Buttons¶
Button Command Object
General¶
Set the Button control values.
Button Control Values¶ Parameter Type Description Name str Title of the button Group str Group name Display int Display title on button (1=Yes, 0=No) Min float Button’s output value when not pressed Max float Button’s output value when pressed
Press the button
Release the button
Press and release the button
Sliders¶
-
class
mhrc.automation.slider.SliderCommands¶ Slider Command Object
General¶
-
SliderCommands.set_value(name=value[, ...])¶ Set the Slider control values.
Slider Control Values¶ Parameter Type Description Name str Title of the button Group str Group name Display int Display title on button (1=Yes, 0=No) Max float Slider’s upper limit Min float Slider’s lower limit Value float Slider’s initial value Units str Units to display in control panel Collect int Data collection (1=continuous, 0=on release)
-
SliderCommands.value(value)¶ Set slider to the given value
Parameters: value (float) – Value to move slider to.
-
SliderCommands.limits(lower, upper)¶ Set slider minumum and maximum limits
Parameters: - lower (float) – Lower slider limit
- upper (float) – Upper slider limit
Dials¶
-
class
mhrc.automation.selector.SelectorCommands¶ Selector Command Object
General¶
-
SelectorCommands.set_value(name=value[, ...])¶ Set the Selector control values.
Selector Control Values¶ Parameter Type Description Name str Title of the button Group str Group name Display int Display title on button (1=Yes, 0=No) LabelType int Value Display (0=Index, 1=Value, 2=Both) NDP int Number of dial positions (3-10) Value int Initial dial position (1-NDP) conv int Convert output to integer (1=Yes, 0=No) F1 str Output value for Dial position #1 F2 str Output value for Dial position #2 F3 str Output value for Dial position #3 F4 str Output value for Dial position #4 F5 str Output value for Dial position #5 F6 str Output value for Dial position #6 F7 str Output value for Dial position #7 F8 str Output value for Dial position #8 F9 str Output value for Dial position #9 F10 str Output value for Dial position #10
-
SelectorCommands.position(position)¶ Set the selector to the given position
Parameters: position (int) – New position for the dial (1-NDP)
Switches¶
-
class
mhrc.automation.switch.SwitchCommands¶ Switch Command Object
General¶
-
SwitchCommands.set_value(name=value[, ...])¶ Set the Switch control values.
Switch Control Values¶ Parameter Type Description Name str Title of the button Group str Group name Display int Display title on button (1=Yes, 0=No) Value int Initial state (1=On, 0=Off) Max float Switch’s output value when On Min float Switch’s output value when Off Ton str Text for On position Toff str Text for Off position
-
SwitchCommands.set_state(state)¶ Set the switch to the given state
Parameters: state (int) – New state: 1=On, 0=Off
-
SwitchCommands.on()¶ Turn the switch to the On state
-
SwitchCommands.off()¶ Turn the switch to the Off state