The following is a list of terminals for the Squirrel Cage Induction Machine component including a short description:
A, B and C: These terminals are the 3-phase electrical connection points (phases A, B and C) of the stator. A star connected stator is modeled.
When the multi-mass interface is disabled, the following terminal connections are present:
W: Speed input in per-unit. The machine runs at this speed while in speed control mode.
S: A switch to select speed control mode (1) or torque control mode (0).
T: Torque input in per-unit. If the machine is in torque control mode then the machine computes the speed based on the inertia and damping coefficient, this input torque and the output torque.
When the multi-mass interface is enabled, following terminal connections appear.
W: Speed input in per-unit. The machine runs at this speed, which is specified by the multi-mass interface.
Te: Electrical torque output of the machine.
TL: Torque input in per-unit. This torque is passed to the multi-mass interface, which computes the speed based on this torque and parameters within the multi-mass component.