J. R. Carson, Wave Propagation in Overhead Wires with Ground Return, Bell Syst. Techn. J., Vol. 5, pp. 539-554, 1926.
Pollaczek, F., Sur le champ produit par un conducteur simple infiniment long parcouru par un courant alternatif, Revue Gén, Elec., 1931, 29, pp. 851-867.
S. A. Schelkunoff, The electromagnetic theory of coaxial transmission line and cylindrical shields, Bell Syst. Tech. J., vol. 13, pp. 532-579, 1934.
H. W. Bode, Network Analysis and Feedback Amplifier Design, D. Van Nostrand, New York, 1945.
L. M. Wedepohl, Application of Matrix Methods to the Solution of Travelling-Wave Phenomena in Polyphase Systems, Proc. IEE, Vol. 110, No. 12, pp. 2200-2212, December 1963.
H. W. Dommel, Digital Computer Solution of Electromagnetic Transients in Single and Multiphase Networks, IEEE Transactions on Power Apparatus and Systems, PAS-88, #4, pp. 388-399, April 1969.
L. M. Wedepohl, D. J. Wilcox, Transient analysis of underground power-transmission systems. System model and wave-propagation characteristics, Proc. IEE, 120, (2), pp. 253-260, 1973.
W. S. Meyer, H. W. Dommel, Numerical Modelling of Frequency-Dependent Transmission-Line Parameters in an Electromagnetic Transients Program, IEEE Transactions on Power Apparatus and Systems, PAS-93, pp. 1401-1409, Sep./Oct. 1974.
A. Semlyen, A. Dabuleanu, Fast and Accurate Switching Transient Calculations on Transmission Lines with Ground Return Using Recursive Convolutions, IEEE Transactions on Power Apparatus and Systems, Vol. PAS-94, No. 2, pp. 561-571, March/April. 1975.
C. Gary, Approche Complète de la Propagation Multifilaire en Haute Fréquence par Utilisation des Matrices Complexes, EDF Bulletin de la Direction des Études et Recherches-Série B, No. 3/4, pp. 5-20, 1976.
A. Ametani, A General Formulation of Impedance and Admittance of Cables, IEEE Transactions on Power Apparatus and Systems, Vol. PAS-99, No. 3, May/June 1980.
A. Deri, G. Tevan, A. Semlyen, A. Castanheira, The Complex Ground Return Plane – A Simplified Model for Homogeneous and Multi-Layer Earth Return, IEEE Transactions on Power Apparatus and Systems, Vol. PAS-100, No. 8, pp. 3686-3693, August 1981.
J. R. Marti, Accurate Modeling of Frequency Dependent Transmission Lines in Electromagnetic Transients Simulation, IEEE Transactions on Power Apparatus and Systems, PAS-101, #1, pp. 147-155, Jan. 1982.
D. E. Amos, A Portable Package For Bessel Functions Of A Complex Argument And Nonnegative Order, Trans. Math. Software, 1986.
L. M. Wedepohl, Research Report: Calculation of Impedances of Power Cables, University of British Columbia, Submitted to the Manitoba HVDC Research Centre Inc., File E4.151, 1993.
J. J. Grainger, W. D. Stevenson, Power System Analysis, McGraw Hill Inc., 1994.
B. Gustavsen, J. Sletbak, T. Henriksen, Calculation of Electromagnetic Transients in Transmission Cables and Lines Taking Frequency Dependent Effects Accurately Into Account, IEEE Transactions on Power Delivery, Vol. 10, No. 2, April 1995.
L. M. Wedepohl, H. V. Nguyen, G. D. Irwin, Frequency-Dependent Transformation Matrices for Untransposed Transmission Lines using Newton-Raphson Method, IEEE Transactions on Power Systems, Vol. 11, No. 3, pp. 1538-1546, August 1996.
A. M. Gole, Power Systems Transient Simulation, Course Notes, University of Manitoba, 1998.
B. Gustavsen, A. Semlyen, Simulation of Transmission Line Transients Using Vector Fitting and Modal Decomposition, IEEE Transactions on Power Delivery, Vol. 13, No. 2, pp. 605-614, April 1998.
B. Gustavsen, A. Semlyen, Rational Approximation of Frequency Domain Responses by Vector Fitting, IEEE Trans. on Power Delivery, Vol. 14, No. 3, July 1999.
A. Morched, B. Gustavsen, M. Tartibi, A Universal Model for Accurate Calculation of Electromagnetic Transients on Overhead Lines and Underground Cables, IEEE Transactions on Power Delivery, Vol. 14, No. 3, pp. 1032-1038, July 1999.
B. Gustavsen, G. Irwin, R. Mangelrød, D. Brandt, K. Kent, Transmission Line Models for the Simulation of Interaction Phenomena Between Parallel AC and DC Overhead Lines, IPST '99 Proceedings, pp. 61-67, 1999.
L. M. Wedepohl, The Theory of Natural Modes in Multiconductor Transmission Systems, Course Notes, University of Manitoba, 2002.
A. Ramirez, A. Semlyen, and R. Iravani, Order reduction of the dynamic model of a linear weakly periodic system—Part I: General methodology, IEEE Transactions on Power Systems, vol. 19, no. 2, pp. 857–865, May 2004.
B. Gustavsen, Time delay identification for transmission line modeling, in Proc. 8th IEEE Workshop Signal Propagation Interconnects, Heidelber, Germany, pp. 103–106, May 9–12, 2004.
H.M.J. De Silva, A.M. Gole and L.M. Wedepohl, Accurate Electromagnetic Transient Simulations of HVDC Cables and Overhead Transmission Lines, IPST '07 Proceedings, 2007.
B. Gustavsen, J. Nordstrom, Pole Identification for the Universal Line Model Based on Trace Fitting, IEEE Transactions on Power Delivery, vol. 23, no. 1, January 2008.
O. Saad, G. Gaba and M. Giroux, A Closed-Form Approximation for Ground Return Impedance of Underground Cables, IEEE Transactions on Power Delivery, vol. 11, no. 3, July 1996, pp. 1536 - 1545.
Bjorn Gustavsen, Panel Session on Data for Modeling system Transients in Insulated Cables, Power Engineering Society Winter Meeting, 2001. IEEE, Volume 2, pp. 718-723.
L.Marti, R.H. Brierley and T.E. Grainger, Analysis of electromagnetic transients in cross-bonded cable systems using frequency dependent cable models, IPST 1995.
Ametani, A., An Investigation of Earth-Return Impedance Between Overhead and Underground Conductors and Its Approximation, IEEE Transactions on Electromagnetic Compatibility, Vol. 51, Issue: 3, pp. 860 - 867, August 2005.
Uribe F. A., Calculating Mutual Ground Impedances Between Overhead and Buried Cables, IEEE Transactions on Electromagnetic Compatibility, Vol. 50, Issue: 1, pp. 198 - 203, February 2008.
Ametani, A, EMTP Simulations and Theoretical Formulation of Induced Voltages to Pipelines from Power Lines, Session 36, Paper 2, Page 5, 15th PSCC, Liege, 22-26 August 2005.
Jun Zou, JunJie Li, J. B. Lee, and S. H. Chang, Fast and Highly Accurate Algorithm for Calculating the Earth-Return Impedance of Underground Conductors, IEEE Transactions on Electromagnetic Compatibility, Vol. 53, Issue: 1, pp. 237 - 240, February 2011.
Theodoulidis, T. , Exact Solution of Pollaczek’s Integral for Evaluation of Earth-Return Impedance for Underground Conductors, IEEE Transactions on Electromagnetic Compatibility, January 2012.
H.M.J.S.P De Silva, Gole, A.M., Nordstrom, J.E., Wedepohl, L.M., Robust Passivity Enforcement Scheme for Time-Domain Simulation of Multi-Conductor Transmission Lines and Cables, IEEE Transactions on Power Delivery, vol. 25, April 2010.
C. Chen, E. Gad, R. Achar, Passivity Verification in Delay-Based Macromodels of Multiconductor Electrical Interconnects, IEEE Trans. Circuit and systems, vol. 52, October 2005.