Transformer Related References

  1. H. W. Dommel, Digital Computer Solution of Electromagnetic Transients in Single and Multiphase Networks, IEEE Transactions on Power Apparatus and Systems, PAS-88, #4, pp. 388-399, April 1969.

  2. H. W. Dommel, Transformer Models in the Simulation of Electromagnetic Transients, Proc. 5th Power Systems Computing Conference, Cambridge, England, September 1-5, 1975, Paper 3.1/4.

  3. V. Brandwajn, H. W. Dommel, I. I. Dommel, Matrix Representation of Three Phase N-Winding Transformers for Steady State Transient Studies, IEEE Transactions on Power Apparatus and Systems, PAS-101, #6, pp. 1369-1378, June 1982.

  4. D. A. Woodford, Validation of Digital Simulation of DC Links, IEEE Transactions on Power Apparatus and Systems, PAS-104, #9, pp. 2588-2596, September 1985.

  5. W. Enright, O. B. Nayak, G. D. Irwin, J. Arrillaga, An Electromagnetic Transients Model of Multi-limb Transformers Using Normalized Core Concept, IPST '97 Proceedings, Seattle, pp. 93-98, 1997.

  6. W. Enright, N. Watson, O. B. Nayak, Three-Phase Five-Limb Unified Magnetic Equivalent Circuit Transformer models for PSCAD V3, IPST '99 Proceedings, Budapest, pp. 462-467, 1999.

  7. Rezaei-Zare, A., Iravani, R., Sanaye-Pasand, M., Mohseni, H., Farhangi, S., An Accurate Hysteresis Model for Ferro-resonance Analysis of a Transformer, IEEE Transactions on Power Delivery, Vol. 23, No. 3, pp.1448-1456, July 2008.

  8. Chandrasena, W., McLaren, P.G., Annakkage, U.D., Jayasinghe, R.P., An improved low frequency transformer model for use in GIC studies, IEEE Transactions on Power Delivery, Vol. 19, No. 2, pp. 643 - 651, 13-17, April 2004.

  9. Annakkage, U. D., McLaren, P. G., Dirks, E., Jayasinghe, R. P., Parker, A. D., A Current Transformer Model Based on the Jiles–Atherton Theory of Ferromagnetic Hysteresis, IEEE Transaction on Power Delivery, Vol. 15, No. 1, January 2000.

  10. Talukdar, S.N., Bailey, J.R., Hysteresis models for system studies, IEEE Transactions on Power Apparatus and Systems, Vol.95, No.4, pp. 1429- 1434, July 1976.

  11. RTDSĀ® Manual, RTDS Technologies Inc., 100-150 Innovation Drive, Winnipeg, Mantioba, R3T 2E1, Canada.

  12. Samimi, M., Gole, A. M., Jayasinghe, R. P., Improvement of Transformer Saturation Modeling for Electromagnetic Transient Programs, IPST 2013, Vancouver, Canada, July 18-20, 2013.