Requirements

Hardware

 

Category

Requirements

Computer1

Good motherboard with fast front-side speed

8 GB+ of fast, high-quality RAM2

Solid-state hard drive

64-bit operating system

8 CPU cores (minimum 4)3 with a decent CPU ranking

One USB 2.0 port or better (see Legacy Lock-based Licensing below if using)

Internet connection

Usage

 

Category

Requirements

Operating System

Microsoft® Windows 7 SP1 64-bit and Windows 10/Server 2019 64-bit4 (officially supported).

 

Note: It may be possible to run on a virtual machine.

 

The following operating systems may also be used4:  

  • Microsoft® Windows Server 2008 R2 SP1 or better

  • Microsoft® Windows Server 2012

  • Microsoft® Windows Server 2016

  • Microsoft® Windows Server 2022

PSCAD V5 is not supported on any Microsoft® Windows 32-bit edition operating system. Nor is it supported on any of the following:

  • Microsoft® Windows XP

  • Microsoft® Windows Vista

  • Microsoft® Windows 7 SP0

  • Microsoft® Windows 8 and 8.1

Prerequisite Software

Microsoft®  Visual C++ 2022 Redistributables, x86 and x645

Microsoft® .NET Framework 4.8 6

Launching and Running

Microsoft® Windows User privileges

User Profile

Mandatory user profiles are not supported

Licensing

See Licensing.

Third Party Software

A compatible Fortran compiler is required. For details, refer to Selecting and Setting up your Fortran Compiler

Execution Permissions

The application executable files must be white-listed in all protection software:

 

For PSCAD:

 

The path may be set generally, as: %PROGRAMFILES%\PSCAD<version>

 

Or, the path may be specified as:

C:\Program Files (x86)\<version>\bin\win64\pscad.exe

C:\Program Files (x86)\<version>\bin\win\tline.exe

C:\Program Files (x86)\<version>\utilities

 

For the Intel® Parallel Studio Composer Edition for FORTRAN:

%PROGRAMFILES%\Intel

 

For Microsoft® Visual Studio:

%PROGRAMFILES%\Microsoft Visual Studio <version>

 

Allow the user execute permissions to the following within %SYSTEM32%:

cmd.exe

conhost.exe

 

The executable files created by the application must be permitted in all protection software. See listing in Appendix F of the Solutions manual posted in this article.

Folder Permissions

The user must have full permissions for the following folder and sub-folders:

 

Common Documents folder (ex. C:\Users\Public\Documents)

 

The following sub-folders will be created, and the user must have full permissions:

 

C:\Users\<your username>\AppData\Local\Manitoba HVDC Research Centre

C:\ProgramData\Manitoba HVDC Research Centre

Communication Over TCP/IP

This is required for PSCAD and the executables listed in Execution Permissions above, for the purpose of simulation control and data collection for plots.

Network Ports

Ports 30,000 to 40,000 must be available to allow PSCAD and EMTDC communication.

Installation

There are three ways to install the PSCAD application. The following lists the minimum requirements for each method.

General Installation Requirements

 

Category

Requirements

Registry Keys Permissions

32-bit registry keys (used by PSCAD (64-bit)):

 

HKCU\Software\Manitoba HVDC Research Centre\Pscad

HKCU\Software\Manitoba HVDC Research Centre Inc\Pscad

HKLM\Software\Manitoba HVDC Research Centre\Pscad

HKLM\Software\Manitoba HVDC Research Centre Inc\Pscad

 

64-bit registry keys (used by PSCAD (64-bit)):

 

HKCU\Software\Manitoba HVDC Research Centre\Pscad

HKCU\Software\Manitoba HVDC Research Centre Inc\Pscad

HKLM\Software\Manitoba HVDC Research Centre\Pscad

HKLM\Software\Manitoba HVDC Research Centre Inc\Pscad

InstallShield Wizard Installer

 

Category

Requirements

General Requirements

As listed in General Installation Requirements, above

Downloading

Internet connection

Installing (and removing) the Software (PSCAD, License Manager, GFortran, Prerequisites, Sentinel Drivers)

Microsoft® Windows Administrator privileges

Installer Utility

 

Category

Requirements

General Requirements

As listed in General Installation Requirements, above

Downloading

Internet connection

Running

Microsoft®  Windows Administrator privileges

 

The user must have full permissions for the following path:

 

C:\Users\Public\Documents

Logging

The following sub-folder will be created, and the user must have full permissions:

 

C:\Users\<your username>\AppData\Local\Manitoba HVDC Research Centre\Installer

MyUpdater

 

Category

Requirements

General Requirements

As listed in General Installation Requirements, above

Access to Product Downloads

Add the first or both of the following URLs to all anti-virus/firewall whitelists:

 

https://products.pscad.com

ftp://ftps.pscad.com

Installing

Microsoft®  Windows Administrator privileges

Internet connection

Launching (to Install or Update Software)

Microsoft®  Windows Administrator privileges

Internet connection

Launching (to Uninstall Software)

Microsoft®  Windows Administrator privileges

Launching (to Launch Installed Software)

Microsoft®  Windows User privileges (unless otherwise specified)

Connection to Publication Server

Add the first or both of the following URLs to all anti-virus/firewall whitelists:

 

http://publisher.pscad.com:80/

net.tcp://publisher.pscad.com:443/

Supported Protocols

TLS 1.0, TLS 1.1, TLS 1.2

Licensing

There are two ways to license the PSCAD application. The following lists the minimum requirements for each method.

Certificate Licensing

See Certificate Licenses for more details.

 

Category

Requirements

Certificate

MyCentre user account with access to a licensed workgroup.

Operational Requirements

Supported on a local desktop, or remote desktop, or over virtual private network (VPN). Not guaranteed in a cloud desktop environment, but could be verified using diagnostic tools.

Connection to the License Server

Add both of the following URLs to all anti-virus/firewall whitelists:

 

http://licensing.pscad.com:80/Licensing

net.tcp://licensing.pscad.com:443/Licensing

Activate/Release/Refresh a Certificate

Microsoft®  Windows User privileges

Internet connection

Using Certificates

The following sub-folders will be created, FullControl for Everyone is required:

 

C:\Users\<your_user_id>\AppData\Local\Manitoba Hydro International\Licensing\Licenses

 

The following sub-folder should already exist, and will be used:

 

C:\ProgramData\Microsoft\Crypto\RSA\MachineKeys

 

(required permissions: Read, Write for everyone)

Supported Protocols

TLS 1.0, TLS 1.1, TLS 1.2

Legacy Lock-Based Licensing

There are two ways that lock-based licensing may be used to license the PSCAD application. The following lists the minimum requirements for each method.

 

General Lock-Based Licensing Requirements

 

Category

Requirements

Licensing Media

The License Database File must be installed on the licensed machine

The Sentinel USB Lock must be installed on the licensed machine

To Communicate with the Sentinel Lock

Sentinel Driver software to use the Sentinel USB lock7

 

For Microsoft® Windows 10 (all releases):

  • Sentinel System Driver 7.6.0 or better is required8

  • For Microsoft® Windows 10 Build 1803 or better, Sx32w.dll, version 7.1.0.14 is required

One USB 2.0 port or better.

To Install a License Database File

Microsoft® Windows Administrator privileges

To Use the License Update Tool

Microsoft® Windows Administrator privileges

Internet connection is required if downloading the posted (current) version

To Activate a License

Microsoft® Windows User privileges

Access to Obtain and Retain Licensing Settings

Settings accessible to everyone on the specified machine:

 

HKEY_LOCAL_MACHINE\SOFTWARE\Manitoba HVDC Research Centre Inc\PSCAD\License

 

Note: Microsoft® Windows Administrator privileges are required to modify them.

 

Settings applicable only to specified individuals on a machine:

 

HKEY_CURRENT_USER\Software\Manitoba HVDC Research Centre Inc\PSCAD\License

 

Note: Only Microsoft® Windows User-level privileges are required to read or modify them, unless prohibited by a group policy.

 

Single-User Lock-Based Licensing Requirements

 

Category

Requirements

General Requirements

As listed in General Lock-based Licensing Requirements, above

Machine

Supported on a local machine, but may be possible to use virtual private network (VPN) to remote log in.

 

Not supported in a cloud desktop environment.

Firewall

Ports 2053 and 2054 must be open

Standalone License Manager (see The License Manager section)

Must be installed if the PSCAD license contains more than one PSCAD seat.

 

Multi-User Lock-Based Licensing Requirements

 

Category

Requirements

General Requirements

As listed in General Lock-based Licensing Requirements, above

Machine – Client

Supported on a local machine, but may be possible to use virtual private network (VPN) to connect to the server.

 

Not supported in a cloud desktop environment (generally they are not connected to the corporate network).

 

Internet connection is required if using VPN for a remote License Manager

Machine – Server

Supported on a physical machine, but may be possible to use a virtual server. Contact the PSCAD Support Desk support@mhi.ca for details.

License Manager Software

Must be installed as applicable:

  • On the server, if the license is hosted on the server and shared over the network with client machines

  • On the client machine, if the license is used locally on the client machine and has more than one seat

ICMP Ping Echo and ICMP Ping Reply

Must be enabled on the firewall for the host and client machines

TCP/IP and UDP/IP on Ports 2053 / 2054

Must be open on the firewall

NetBIOS (if used) Port 137

Must be allowed on the server

The License Manager

Required when using Multi-User Licensing.

 

Category

Requirements

Operating System

Recommended on the following Microsoft® Windows operating systems:

  • Microsoft® Windows 7 SP1

  • Microsoft® Windows 10

  • Microsoft® Windows Server 2016

The following operating systems may also be used:

  • Microsoft® Windows Server 2008 R2 SP1 or better

  • Microsoft® Windows 11

  • Microsoft® Windows Server 2012 R2

  • Microsoft® Windows Server R2016

  • Microsoft® Windows Server 2022 (not tested yet)

The License Manager is not supported or not recommended on the following operating systems:

  • Microsoft® Windows XP

  • Microsoft® Windows Vista

  • Microsoft® Windows 7 SP0

  • Microsoft® Windows 8 and Windows 8.1

Supported on a physical machine, but may be possible to use a virtual server. The USB lock must be connected. Contact the PSCAD Support Desk support@mhi.ca for details.

Installation

Microsoft® Windows Administrator privileges

IP Address

If the License Manager is to be installed on a license host machine (server), the IP address must be static

 

Sleep/Hibernate

If the License Manager is to be installed on a license host machine (server), the server must not be allowed to sleep or hibernate

Start/Stop/Restart the License Manager

Microsoft® Windows Administrator privileges

License Manager Setup Tool

Microsoft® Windows Administrator privileges.

 

Internet connection is required if downloading the posted (current) version

Running/Restarting the License Manager

Whitelist the License Manager executable files in this folder:


C:\Program Files (x86)\HVDC Lmgr\WinNT

TCP/IP and UDP/IP on Ports 2053/2054

Must be open on the firewall

Diagnostic Tools

Category

Requirements

Running the Get Info tool

Microsoft®  Windows User privileges if it will be used only to gather and display system.

 

Microsoft® Windows Administrator privileges if it will be used to make any modifications.

 

Internet connection is required if downloading the posted (current) version

Running the Fortran Medic Tool

Microsoft®  Windows User privileges

Internet connection is required if downloading the posted (current) version

 

Notes:

  1. PSCAD is a numerically intensive power system transients simulator; a fast and efficient personal computer is recommended for best results. To obtain specifications for extremely high workloads, please contact the PSCAD Support Desk for information (support@mhi.ca).

  2. Personal computers configured with slower processors and lesser RAM may be used, but slower execution performance will result.  In other words, simulation speed increases with processor speed and amount of installed RAM.

  3. Generally, the faster the better. We recommend an eight-core processor (or at least a four-core processor) to take advantage of Parallel and High Performance Computing. Additional licensed capabilities may be purchased to maximize these features. For more information, refer to this topic or contact the Support Desk (support@mhi.ca).

  4. PSCAD v5.0.0 is not supported on 32-bit operating systems.

  5. Both the 32-bit and 64-bit editions of Visual C++ Redistributables are required on your Windows 64-bit Operating System. If this prerequisite software is not already installed, the user will be prompted to install it when PSCAD is installed.

  6. If Microsoft® .NET Framework 4.8 is not already installed, the user will be prompted to install it when PSCAD is installed.

  7. Sentinel Driver software is installed automatically alongside PSCAD and the License Manager.

  8. Sentinel Driver version 7.6.0 is deployed with PSCAD 5.0.0 and License Manager v1.45 and better.