The properties contained within the Dynamics section are related to the EMTDC system dynamics. These are explained below.
The input parameters involved here are outlined below.

When this control is enabled, all declared data signal variables (be they feed-forward or feed-back signals), will be transferred to and from their designated EMTDC storage array each time step. If this control is disabled, only those declared variables that must be transferred to storage (such as feed-back signals) are considered; all other variables are deemed temporary and are discarded at the end of each time step.
NOTE: It is important to note that tool tips (flybys extract the value of the signal being monitored from storage. Therefore, if this control is disabled, all feed-forward signal values will not appear in the tool tips!
In smaller projects, toggling this control will have very little effect on the simulation speed. As projects become larger and contain many control signals, this feature may help to speed things up.
EXAMPLE 7-3:
In the simple control system shown below, there will be a total of four,
type REAL variables declared in the project Fortran file when this project
is compiled: In1, error, Out
and In2. Three are feed-forward
variables (indicated by the
symbol), and one is a feedback variable (indicated by the
symbol).

NOTE: Users can display these symbols at any time by enabling the Show Signal Locations parameter in the Module Settings dialog. For a more detailed description of these symbols, see Show Signal Locations in Chapter 11 of this manual.
If Store Feed Forward Signals for Viewing is enabled, all four of the above variables will be stored every time step, as indicated in the following excerpt from the project FORTRAN file:
!======================================================================= SUBROUTINE DSDyn() . . . !--------------------------------------- ! Transfers from storage arrays !--------------------------------------- In2 = STOF(ISTOF + 1) In1 = STOF(ISTOF + 2) error = STOF(ISTOF + 3) Out = STOF(ISTOF + 4) . . . !--------------------------------------- ! Feedbacks and transfers to storage !--------------------------------------- STOF(ISTOF + 1) = In2 STOF(ISTOF + 2) = In1 STOF(ISTOF + 3) = error STOF(ISTOF + 4) = Out
|
If Store Feed Forward Signals for Viewing is disabled, only the feedback variable Out will be written to storage every time step as indicated in the following excerpt from the project FORTRAN file:
!======================================================================= SUBROUTINE DSDyn() . . . !--------------------------------------- ! Transfers from storage arrays !--------------------------------------- Out = STOF(ISTOF + 4) . . . !--------------------------------------- ! Feedbacks and transfers to storage !--------------------------------------- STOF(ISTOF + 4) = Out
|
The input parameters involved here are outlined below.

Select this option to show signal flow direction on control signal Wires (i.e. Wires carrying REAL, INTEGER or LOGICAL data types). See Control Signal Pathways for more details on this.
The input parameters involved here are outlined below.

Select this option to treat multiple buses with the same name as the same bus. That is graphically separated bus points with the same name will represent the same EMTDC node points in the electrical grid. See the Bus component for more.