Fast Fourier Transform (FFT)

 

Description

This is an online Fast Fourier Transform (FFT), which can determine the harmonic magnitude and phase of the input signal as a function of time. The input signals are first sampled before they are decomposed into harmonic constituents.

 

Options are provided to use one, two or three inputs. In the case of three inputs, the component can provide output in the form of sequence components.

 

The user may select one of the following three FFT block types:

The sequence components are computed based on the simple transformation equation:

 

NOTE:  Due to the discrete nature of the algorithm, any sub-harmonics or inter-harmonics present in the measured signal will interfere with the output. The measured signal should be free from inter-harmonics and sub-harmonics for accurate results.