
This component is a binary-logic, edge-triggered monostable multivibrator. A positive edge on the input results in the output going high and remaining high for a set time (Pulse Duration), after being turned on.
If the input should go high again before the set time has elapsed, the monostable is re-triggered and stays high for the set time following the positive edge of the new high.
If Interpolation Compatibility is enabled, then the interpolated information is generated by the device and sent to the output. The output interpolated time is based on the input interpolated time, the user input delay, and the simulation time step. When full interpolation is utilized, this device is very accurate even at larger time steps.
More: |