Simulation Sets

class mhi.pscad.SimulationSet

Simulation Set

A container of Project and External Simulation Set Tasks

Management

SimulationSet.name(new_name: str = None) → str

Get or set the simulation set name.

Parameters

new_name (str) – New name for the simulation set (optional)

Returns

The name of the simulation set

Tasks

SimulationSet.tasks() → List[mhi.pscad.ProjectTask]

List projects included in the simulation set.

Returns

The tasks included in the simulation set.

Return type

List[ProjectTask]

SimulationSet.list_tasks() → List[str]

List task names included in the simulation set.

Returns

The names of the tasks in the simulation set.

Return type

List[str]

SimulationSet.add_tasks(*tasks: Union[str, Project]) → None

Add one or more tasks (projects) to the simulation set.

Parameters

*tasks – The tasks (projects) to add to the simulation set.

SimulationSet.remove_tasks(*tasks: Union[str, Project, ProjectTask, ExternalTask]) → None

Remove one or more tasks (projects) from the simulation set.

Parameters

*tasks – The tasks (projects) to remove from the simulation set.

SimulationSet.task(name: str) → mhi.pscad.ProjectTask

Retrieve an individual task in the simulation set.

Parameters

task_name (str) – Name of task

Returns

The identified task

Return type

ProjectTask

Build & Run

SimulationSet.run(consumer=None) → None

Run this simulation set.

Parameters

consumer – handler for events generated by the build/run (optional).

Simulation Tasks

Project Task

class mhi.pscad.ProjectTask

Project Simulation Set Task

ProjectTask.name

Name of this project task

ProjectTask.namespace() → str

Get the namespace of the task

ProjectTask.simulation_set

Simulation set the task is part of

ProjectTask.parameters(parameter=value, ...)

Get/set simulation set task parameters

Project Task Parameters

Param Name

Type

Description

namespace

str

Namespace of project (read-only)

name

str

Display Name

ammunition

int

Task count

volley

int

Maximum Volley

affinity

int

Trace Affinity

rank_snap

bool

Specify snapshot file by rank #?

substitutions

str

Substitution set

clean

bool

Force Re-Build

ProjectTask.layers(layer_name=state, ...)

Get / set layer overrides for this Simulation Task.

Each layer can be forced into state different from the project’s default state.

Layer State Overrides

State

Description

None

Inherit from the project’s layer state

True

Force the layer to be enabled

False

Force the layer to be disabled

"Custom"

Force the layer into the configuration named “Custom”

Returns

The current simulation task’s layer overrides.

Return type

dict

Example:

# When this simulation set task runs, force the "region1" layer
# to be enabled, the "region2" layer to be disabled, and the
# "region3" layer into a custom layer configuration.  Remove any
# override that was previously applied to "region4" in this task.

task.layers(region1=True, region2=False, region3="Special",
            region4=None)
ProjectTask.overrides(parameter=value, ...)

Get / set override parameters for this Simulation Task.

Project Task Override Parameters

Parameter Name

Type

Description

duration

float

Duration of run (sec)

time_step

float

Simulation time-step (µs)

plot_step

float

Output channel plot step

start_method

int

Startup Method. 0=Standard, 1=From Snapshot

startup_inputfile

str

Input filename

save_channels_file

str

Output filename

save_channels

int

0=Do not save, 1=Legacy Format (*.out), 2=Advanced Format (*.psout)

timed_snapshots

int

0=None, 1=Single, 2=Incremental (Same File), 3=Incremental (Many Files)

snapshot_file

str

Snapshot filename

snap_time

float

Snapshot time

run_config

int

0=Standalone, 1=Master, 2=Slave

run_count

int

Number of runs

remove_snapshot_offset

bool

Remove snapshot time offset

only_in_use_channels

bool

Only send “in use” channels

state_animation

bool

Enable animation

manual_start

bool

Manual Start

For each of the above parameters, there is an additional parameter, prefixed with override_, which controls whether this parameter is used. It is automatically set to "true" if a value other than None is given, and to "false" if the None value is given.

External Task

class mhi.pscad.ExternalTask

External Simulation Set Task