Output File Format

 

The output file formats vary for the Interface to Harmonic Impedance Solution component, depending on the set input parameters and how many phases the component is connected to.  Some of the possible output file formats are explained in the following sections.

+ve, -ve and 0 Sequence Impedances

If the Output Impedance Type input parameter is set to +ve, -ve and 0 Sequence Impedances, then output file will be in simple columnar format with the columns labelled as follows from left to right:

 

Column 1

 

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

Frequency

Zero Sequence Impedance Magnitude

Zero Sequence Impedance Phase

Positive Sequence Impedance Magnitude

Positive Sequence Impedance Phase

Negative Sequence Impedance Magnitude

Negative Sequence Impedance Phase

 

The units for the magnitude and phase values are determined by the Impedance Output Units input parameter.  The frequency units are determined by the Frequency Output Units input parameter.

Phase Impedances

If the Output Impedance Type input parameter is set to Phase Impedances, then output file will be in the following format:

 

Column 1

 

Column 2

Column 3

Column 4

Column 5

Column 6

Column 7

 

 

Impedance Matrix

 

Frequency

Impedance Magnitude

|Z11|

Phase Angle

f11

 

 

 

 

Impedance Magnitude

|Z21|

Phase Angle

f21

Impedance Magnitude

|Z22|

Phase Angle

f22

 

 

Impedance Magnitude

|Z31|

Phase Angle

f31

Impedance Magnitude

|Z32|

Phase Angle

f32

Impedance Magnitude

|Z33|

Phase Angle

f33

 

The units for the magnitude and phase values are determined by the Impedance Output Units input parameter.  The frequency units are determined by the Frequency Output Units input parameter.

NOTE:  As this matrix is symmetrical, the upper part is not shown.  For systems with more than three phases, this impedance matrix will expand accordingly.

 

Related Topics

  1. Interface to Harmonic Impedance Solution