This component does a linear transformation of the input signal in y = mx + c form. The transformation can be specified as gain and intercept, or by two points.
Name |
Text |
|
Optional text parameter for identification of the component. |
|
|
|
|
|
|
Dimension |
Integer |
Literal |
Enter the dimension of the input/output signal. |
|
|
|
|
|
|
Configuration Method |
|
Choice |
|
Select Slope and Intercept or Two Points. |
|
|
|
|
|
Slope |
|
Real |
Constant |
Slope of the transformation equation.
Enabled only if Configuration Method | Slope and Intercept is selected. |
|
|
|
|
|
Intercept |
|
Real |
Constant |
Intercept of the transformation equation.
Enabled only if Configuration Method | Slope and Intercept is selected. |
|
|
|
|
|
X1 |
|
Real |
Constant |
X coordinate of the first point.
Enabled only if Configuration Method | Two Points is selected. |
|
|
|
|
|
Y1 |
|
Real |
Constant |
Y coordinate of the first point.
Enabled only if Configuration Method | Two Points is selected. |
|
|
|
|
|
X2 |
|
Real |
Constant |
X coordinate of the second point.
Enabled only if Configuration Method | Two Points is selected. |
|
|
|
|
|
Y2 |
|
Real |
Constant |
Y coordinate of the second point.
Enabled only if Configuration Method | Two Points is selected. |