A hysteresis controller is a component that takes an input and produces an output based on predefined thresholds. It switches the output between two states when the input crosses these thresholds, preventing rapid fluctuations.
|
Name for Identification |
Text |
Optional text parameter for identification of the component. |
||
|
|
|
|
|
|
|
Model Selection |
Choice |
Selected from Simple or Generic. Simple gives constant output outside the transition range. |
||
|
|
|
|
|
|
|
Input ON Threshold |
|
REAL |
Constant |
Enter the input ON threshold. Visible only if Model Selection | Simple is selected. |
|
|
|
|
|
|
|
Input OFF Threshold |
|
REAL |
Constant |
Enter the input OFF threshold. Visible only if Model Selection | Simple is selected. |
|
|
|
|
|
|
|
Output Value When ON |
|
REAL |
Constant |
Enter the value of output when ON. Visible only if Model Selection | Simple is selected. |
|
|
|
|
|
|
|
Output Value When OFF |
|
REAL |
Constant |
Enter the value of output when OFF. Visible only if Model Selection | Simple is selected. |
|
|
|
|
|
|
|
Input at Bottom Left Point |
|
REAL |
Constant |
Enter the input value at the Bottom Left Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Output at Bottom Left Point |
|
REAL |
Constant |
Enter the output value at the Bottom Left Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Input at Bottom Right Point |
|
REAL |
Constant |
Enter the input value at the Bottom Right Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Output at Bottom Right Point |
|
REAL |
Constant |
Enter the output value at the Bottom Right Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Input at Top Right Point |
|
REAL |
Constant |
Enter the input value at the Top Right Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Output at Top Right Point |
|
REAL |
Constant |
Enter the output value at the Top Right Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Input at Top Left Point |
|
REAL |
Constant |
Enter the input value at the Top Left Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Output at Top Left Point |
|
REAL |
Constant |
Enter the output value at the Top Left Point. Visible only if Model Selection | Generic is selected. |
|
|
|
|
|
|
|
Fortran Comment |
Text |
Optional comment line for the source code generated. |
||
|
|
|
|
|
|
|
Dimension |
|
INTEGER |
Literal |
Enter the dimension of input/output signals. |