This component can be one of nine types of 2nd order filter:
Low Pass
Mid Pass
High Pass
High Reject
Mid Reject
Low Reject
High Reject
Mid Reject
Low Reject
Frequencies below the characteristic frequency are referred to as low frequencies; those near the characteristic frequency are referred to as mid-frequencies; those above are referred to as high.
Function types 7,8 and 9 are similar to 4, 5 and 6, with the exception of a 180° phase-shift for the upper half of the passed frequencies. The type of filter is determined by the input parameter Function Code, which lies in the range of 1 to 9.
More: |
Name for Identification |
Text |
Optional text parameter for identification of the component. |
||
Gain |
|
REAL |
Variable |
Gain factor |
|
|
|
|
|
Damping Ratio |
|
REAL |
Variable |
Damping ratio |
|
|
|
|
|
Characteristic Frequency |
|
REAL |
Variable |
Characteristic frequency [Hz] |
|
|
|
|
|
Function Code |
|
Choice |
|
Selects filter function type. Can be 1 to 9. See Filter Functions for more details |
|
|
|
|
|
Dimension |
|
INTEGER |
Literal |
Enter the dimension of the input/output signals. |