Component Wizard#

class mhi.pscad.wizard.UserDefnWizard(name: str, *, module: bool = False)#

User Definition construction wizard

Usage:

wizard = UserDefnWizard("definition_name")
wizard.description = "A multiplicative gain factor component"
wizard.port.input(-2, 0, "In", Signal.REAL)
wizard.port.output(2, 0, "Out", Signal.REAL)
config = wizard.category.add("Configuration")
config.real('Gain', description="Gain factor")
wizard.graphics.text("Gain", 0, 4)
wizard.script['Fortran'] = "      $Out = $In * $Gain"

defn = wizard.create_definition(project)

canvas.create_component(defn, x, y)

Added in version 2.2.

name#

Definition name (hint)

When the definition is created, PSCAD may change the definition name to ensure it is unique.

property module: bool#

Flag indicating this definition will be a module with a user canvas.

Added in version 2.5.

description#

Component definition description

property port#

Port container.

Use

to add new inputs, outputs, and electrical connection ports.

Use wizard.port["name"] to access a Port by name.

Since the same port name may exist multiple times with different enable condtions, use for port in wizard.port: to iterate over all defined ports.

property graphics#

Graphics container.

The current defined graphic shapes (excluding port lines & arrows) may be iterated over using for shape in wizard.graphics:

Use

to add new text, lines, arrows, and rectangles.

Note

Lines & arrows will be created for ports automatically.

form_caption#

Parameter Form’s Caption

form_width#

Parameter Form’s width

form_height#

Parameter Form height

form_splitter#

Parameter Form default splitter position

form_category_width#

Parameter Form’s category tree width

form_help_width#

Parameter Form’s dynamic help panel width

property category#

Component parameter form category container

Use wizard.category.add("category_name", ...), to add categories to the form. Parameters may then be added to that category object.

Use wizard.category["name"] to access a category by name.

property parameter#

Component parameter container

Using wizard.parameter["name"] to access an existing parameter.

Note

Parameters can only be added to a category object. Use wizard.category.add(...) to create the category, then add parameters to that category object.

property script#

Component scripts container

Use wizard.script['Fortran'] = '''...''' to set a script section.

Valid sections are: Branch, Checks, Computations, Dsdyn, Dsout, Fortran, MANA, Matrix-Fill, Model-Data, T-Lines, Transformers Help, FlyBy, and Comments.

create_definition(prj: Project, *, create_leads: bool = True) Definition#

Create the definition in the given project.

Once the desired ports, graphics, and form parameters & categories have been added to the wizard, this method will create the required component definition in the given project, which may then be used to create instances of the component.

Note

The definition name configured in the wizard is only a hint. When PSCAD creates the definition, it may change the definition name, so refer to the returned definition for the actual definition name.

Changed in version 2.9.6: create_leads parameter may be set to False to prevent creation of default “port lead” graphics.

Ports#

class mhi.pscad.wizard.UserDefnWizard.Ports#

Port Container, accessed using the wizard.port property.

Use wizard.port["name"] to access a Port by name.

Since the same port name may exist multiple times with different enable condtions, use for port in wizard.port: to iterate over all defined ports.

electrical(x: int, y: int, name: str, electrical_type: str | Electrical = 'FIXED', dim: int = 1, enable: str = 'true', internal: bool = False)#

Create a new electrical connection port

input(x: int, y: int, name: str, data_type: str | Signal, dim: int = 1, enable: str = 'true', arrow: bool | Tuple[int, int] = True)#

Create a new control signal input port

output(x: int, y: int, name: str, data_type: str | Signal, dim: int = 1, enable: str = 'true', arrow: bool | Tuple[int, int] = False)#

Create a new control signal output port

Port#

class mhi.pscad.wizard.UserDefnWizard.Port#

Component Input/Output/Electrical connections

data_type#

I/O port data type (BOOLEAN, INTEGER, REAL, COMPLEX)

dim#

Port dimension.

A dimension of 1 indicates a scalar wire connection. A dimension greater than 1 indicates an array wire connection. A dimension of 0 inherits the dimesion of the connected wire.

electrical_type#

Electrical port type (FIXED, SWITCHED, REMOVABLE)

enable#

Port enable condition

internal#

Used to create electrical nodes with no outside connection

mode#

Port node type (ELECTRICAL, INPUT, OUTPUT)

name#

Port name

property side#

Port label location (NONE, LEFT, ABOVE, BELOW, RIGHT, AUTO)

x#

Port X coordinate

y#

Port Y coordinate

Graphics#

class mhi.pscad.wizard.UserDefnWizard.Graphics#

Container for graphical elements, accessed using the wizard.graphics property.

The current defined graphic shapes (excluding port lines & arrows) may be iterated over using for shape in wizard.graphics:

arrow(x1: int, y1: int, x2: int, y2: int, length: int = 5, width: int = 5, *, enable: str = 'true', color: str = 'black', line_style: str | LineStyle = LineStyle.SOLID, thickness: int = 0, port: str = '')#

Create an arrow from [x1,y1] to [x2,y2].

line(x1: int, y1: int, x2: int, y2: int, *, enable: str = 'true', color: str = 'black', line_style: str | LineStyle = LineStyle.SOLID, thickness: int = 0, port: str = '')#

Create a line between [x1,y1] and [x2,y2].

rectangle(x1: int, y1: int, x2: int, y2: int, enable: str = 'true', color: str = 'black', line_style: str | LineStyle = LineStyle.SOLID, thickness: int = 0, port: str = '', foreground: str = 'Black', background: str = 'White', fill_style: int = 0)#

Create a rectangle between corners [x1,y1] and [x2,y2].

text(text: str, x: int = 0, y: int = 5, *, color: str = 'Black', enable: str = 'true', angle: int = 0, anchor: str | Align = Align.CENTER, full_font: str = 'Tahoma, 12world')#

Create a text label.

Text#

class mhi.pscad.wizard.UserDefnWizard.Text#

A text label

anchor#

Text anchor (LEFT, CENTER, RIGHT)

angle#

Text angle (degrees)

color#

Color

enable#

Text visibility condition

full_font#

Text Font

text#

Text label

x#

X coordinate

y#

Y coordinate

Line#

class mhi.pscad.wizard.UserDefnWizard.Line#

A straight line

color#

Color

enable#

Visibility condition

line_style#

Line style (SOLID, DOT, DASH, DOTDASH)

port#

Associated port name (for line thickness)

thickness#

Line thickness

0

0.2pt

1

0.4pt

2

0.6pt

3

0.8pt

4

1.0pt

5

1.2pt

6

1.4pt

7

Associated Port

x#

X coordinate

y#

Y coordinate

Rectangle#

class mhi.pscad.wizard.UserDefnWizard.Rectangle#

An axis-aligned rectangle.

background#

Background fill color

color#

Color

enable#

Visibility condition

fill_style#

Fill style (SOLID, HOLLOW, CROSS, HORIZONTAL, VERTICAL, …)

foreground#

Foreground fill color

height#

Height

line_style#

Line style (SOLID, DOT, DASH, DOTDASH)

port#

Associated port name (for line thickness)

thickness#

Line thickness

0

0.2pt

1

0.4pt

2

0.6pt

3

0.8pt

4

1.0pt

5

1.2pt

6

1.4pt

7

Associated Port

width#

Width

x#

X coordinate

y#

Y coordinate

Parameter Form#

class mhi.pscad.wizard.UserDefnWizard.Parameters#

Parameters container, accessed using the wizard.parameter property.

Note

Parameters can only be added to a category object. Use wizard.category.add(...) to create the category, then add parameters to that category object.

keys() List[str]#

List of parameter names

Categories#

Category#

class mhi.pscad.wizard.UserDefnWizard.Category#

Component parameter form category, accessed using the wizard.category property.

After creating a category using category = wizard.category.add("category_name", ...), use

to add parameters to that category.

Properties#

Category.name#

Category Name

Category.level#

Category Level, for indenting category tree nodes

Category.enable#

Category enable condition

Methods#

Category.text(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, value: str = '', help: str | None = None, help_mode: str | None = None, regex: str | None = None, allow_empty_strings: bool = True, minimum_length: int | None = None, maximum_length: int | None = None, error_msg: str | None = None)#

Add a text parameter to the category

Category.logical(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animate_condition: str | None = None, animated: bool = False, content_type: str = 'Literal', dimension: int = 1, intent: str = 'Input', value: str = '.TRUE.', help: str | None = None, help_mode: str | None = None)#

Add a logical parameter to the category

Changed in version 3.0.9: Added animate_condition, animated, content_type, dimension, and intent arguments.

Category.boolean(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animated: bool = False, true_text: str = 'Show', false_text: str = 'Hide', value: str = 'true', help: str | None = None, help_mode: str | None = None)#

Add a boolean parameter to the category.

By default, boolean parameters display Show or Hide when true or false, but these may be changed using the true_text="...", false_text="..." parameters.

Changed in version 3.0.9: Added animated argument; default value changed from '.TRUE.' to 'true'.

Category.choice(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animated: bool = False, choices: Dict[int, str], value: str = '', help: str | None = None, help_mode: str | None = None)#

Add a choice parameter to the category.

The choices must be specified by passing a dictionary to the choices={...} parameter. Dictionary keys should be integers, and the values the text to display for each key.

Changed in version 3.0.9: Added animated argument.

Category.integer(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animate_condition: str | None = None, animated: bool = False, content_type: str = 'Literal', dimension: int = 1, intent: str = 'Input', minimum: int = -2147483648, maximum: int = 2147483647, value: int = 0, help: str | None = None, help_mode: str | None = None)#

Add an integer parameter to the category.

Changed in version 3.0.9: Added animate_condition, animated, content_type, dimension, and intent arguments; default minimum changed from -2147483647 to -2147483648.

Category.real(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animate_condition: str | None = None, animated: bool = False, content_type: str = 'Literal', dimension: int = 1, intent: str = 'Input', minimum: float = -1e+308, maximum: float = 1e+308, units: str | None = None, value: float = 0.0, help: str | None = None, help_mode: str | None = None)#

Add a real parameter to the category.

Changed in version 3.0.9: Added animate_condition, animated, dimension, and intent arguments.

Category.complex(name: str, *, description: str | None = None, group: str = '', enable: str | None = None, visible: str | None = None, animate_condition: str | None = None, animated: bool = False, content_type: str = 'Literal', dimension: int = 1, intent: str = 'Input', minimum: float = -1e+308, maximum: float = 1e+308, units: str | None = None, value: str = '0.0, 0.0', help: str | None = None, help_mode: str | None = None)#

Add a complex parameter to the category.

Added in version 3.0.9.

Parameters#

class mhi.pscad.wizard.UserDefnWizard.Categories#

Component parameter form category container, accessed using the wizard.category property.

add(name, *, enable: str = 'true', level: int | None = None)#

Add a new category

keys() List[str]#

List of Form Category names

Parameter#

class mhi.pscad.wizard.UserDefnWizard.Parameter#

Component parameter

allow_empty_strings#

Is Text Parameter allowed to be empty?

animate_condition#

Condition in which this property is actively animating

Added in version 3.0.9.

animated#

Whether this value could be animated while running

Added in version 3.0.9.

property choices#

Choice parameter choices

content_type#

Parameter content_type ('Literal', 'Constant' or 'Variable')

description#

Parameter description

dimension#

Parameter dimension. If this parameter is to carry an array signal, then this input specifies the dimension of the array.

Added in version 3.0.9.

enable#

Parameter enable condition

error_message#

Text Parameter invalid input error message

group#

Parameter group

help_mode#

Parameter help mode ('Append' or 'Overwrite')

help_text#

Parameter Help text

intent#

Parameter intent ('Input' or 'Output')

Added in version 3.0.9.

maximum#

Parameter maximum limit

minimum#

Parameter minimum limit

name#

Parameter name

regex#

Text Parameter regular-expression filter

type#

Type of the Parameter

units#

Parameter units

value#

Parameter value

visible#

Parameter visibility condition

Scripts#

class mhi.pscad.wizard.UserDefnWizard.Scripts#

Script Section container

items() Iterable[Tuple[str, str]]#

Generator of script name/value pairs

keys() List[str]#

Currently defined script section names